96
Configuring the AT-EXLS-3000 System
Redundancy Fields for Primary Switch
Table 23 lists all available options under the
Redundancy
configuration screen fields.
Field
Description
Enable Mega
Redundancy
Select this field to enable redundancy.
Mega Peer IP
IP address of the AT-EXLS-3000 device on the LAN.
Reference IP
IP address of a reference device on the LAN. This is used to test
connectivity to the LAN. The reference device must be
operational and respond to pings.
LAN Connection
Timeout
Interval in seconds before a timeout state occurs. The default is
10 seconds.
Table 23: Redundancy Configuration Tab Parameters for a Primary Cascade Switch
Once the changes are made, you must click Save, then go to System Tools and apply changes as
described in the Apply section, in order for them to take effect.
When a switch failure or a link failure has been detected, a failover occurs, and the switch that
remains fully operational goes into standalone mode.
!
Once the fault that caused the switchover has been resolved, both switches must be
rebooted in order for them to return to normal cascade operation. Otherwise, they
will continue to operate in standalone mode.