AT-GS950/16PS Switch Web Interface User’s Guide
121
4. Under the
Loopback Detection Global Settings
, configure the
following parameters:
Interval:
This parameter sets the interval of time that the ports are
tested. The range is 1 to 32767 seconds.
Recover Time:
This parameter sets the amount of time that the
port will take to recover once the loopback condition has been
removed. The range is 60 to 1000000 seconds.
If the
Recover Time
is set to 0, the port recovery is disabled until it
is manually reset. It can be reset by re-configuring the
Recover
Time
to its normal operating range or by disabling the Loopback
Detection feature on the switch.
5. Click the
Apply
button just above the
Action
column in the table at the
bottom of the page.
The
Loopback Detection Global Settings
parameters becomes
active.
6. In the table at the bottom of the page, select one of the
Loopback
Detection State
choices from the pull down menu:
Ignore:
This parameter indicates that the setting in the
All
row
does not apply to the
Loopback Detection State
field. In other
words, each port is set individually.
Enabled:
This selection enables the Loopback Detection feature
for each port. This state must be enabled along with the
State
field
at the top of the page before this feature can be active on the
selected port.
Disabled:
This selection disables the Loopback Detection feature
on the selected port.
Note
In the
All
row when you select
Enable
or
Disable
instead of
Ignore
,
the selection applies to all of the AT-GS950/16PS switch ports.
7. Click the
Apply
button in the Action column of the table.
8. Repeat steps 6 and 7 for other individual port settings.
9. From the main menu on the left side of the page, select
Save
Configuration to Flash
to permanently save your changes.
Summary of Contents for AT-GS950/16PS
Page 12: ...Figures 12...
Page 14: ...List of Tables 14...
Page 18: ...Preface 18...
Page 20: ...20...
Page 52: ...Chapter 2 System Configuration 52...
Page 54: ...54...
Page 92: ...Chapter 5 Multiple Spanning Tree Protocol 92...
Page 102: ...Chapter 6 Static Port Trunking 102...
Page 118: ...Chapter 8 Port Mirroring 118...
Page 140: ...Chapter 11 IGMP Snooping 140...
Page 174: ...Chapter 14 GVRP 174...
Page 186: ...Chapter 15 Quality of Service and Cost of Service 186...
Page 188: ...188...
Page 216: ...Chapter 17 SNMPv3 216...
Page 244: ...Chapter 18 Access Control Configuration 244...
Page 282: ...Chapter 21 Security 282...
Page 288: ...Chapter 22 Power Over Ethernet PoE 288...
Page 289: ...289 Chapter 23...
Page 310: ...Chapter 24 LLDP 310...
Page 322: ...322...
Page 334: ...Chapter 26 Software Configuration Updates 334...
Page 346: ...Chapter 28 Rebooting the AT GS950 16PS 346...
Page 368: ...Appendix A MSTP Overview 368...
Page 386: ...Appendix B AT GS950 16PS Default Parameters 386...