AT-GS950/16PS Switch Web Interface User’s Guide
107
General Guidelines
The following guidelines apply when creating aggregators:
LACP must be activated on both the AT-GS950/16PS
switch and its partner device.
The other device must be 802.3ad-compliant.
The AT-S112 Management software supports up to
eight active ports in an aggregate trunk at a time.
The AT-GS950/16PS Gigabit Ethernet PoE+ Switch
can support up to eight static and LACP aggregate
trunk groups at a time (for example, four static trunks
and four LACP trunks). An LACP trunk is counted
against the maximum number of trunks only when it is
active.
The ports of an aggregate trunk must be the same
medium type: all twisted pair ports or all fiber optic
ports.
The ports of a trunk can be consecutive (for example
ports 1-5) or nonconsecutive (for example, ports 2, 4,
6, 8).
A port can belong to only one aggregator at a time.
A port cannot be a member of an aggregator and a
static trunk at the same time.
The ports of an aggregate trunk must be untagged
members of the same VLAN.
Twisted pair ports must be set to Auto-Negotiation or
1000 Mbps, full-duplex mode. LACP trunking is not
supported in half-duplex mode.
1000Base-X fiber optic ports must be set to full-duplex
mode.
You can create an aggregate trunk of transceivers with
1000Base-X fiber optic ports.
Only those ports that are members of an aggregator
transmit LACPDU packets.
A member port of an aggregator functions as part of an
aggregate trunk only if it receives LACPDU packets
from the remote device. If it does not receive LACPDU
packets, it functions as a regular Ethernet port,
forwarding network traffic while also continuing to
transmit LACPDU packets.
The port with the highest priority in an aggregate trunk
carries broadcast packets and packets with an
Summary of Contents for AT-GS950/16PS
Page 12: ...Figures 12...
Page 14: ...List of Tables 14...
Page 18: ...Preface 18...
Page 20: ...20...
Page 52: ...Chapter 2 System Configuration 52...
Page 54: ...54...
Page 92: ...Chapter 5 Multiple Spanning Tree Protocol 92...
Page 102: ...Chapter 6 Static Port Trunking 102...
Page 118: ...Chapter 8 Port Mirroring 118...
Page 140: ...Chapter 11 IGMP Snooping 140...
Page 174: ...Chapter 14 GVRP 174...
Page 186: ...Chapter 15 Quality of Service and Cost of Service 186...
Page 188: ...188...
Page 216: ...Chapter 17 SNMPv3 216...
Page 244: ...Chapter 18 Access Control Configuration 244...
Page 282: ...Chapter 21 Security 282...
Page 288: ...Chapter 22 Power Over Ethernet PoE 288...
Page 289: ...289 Chapter 23...
Page 310: ...Chapter 24 LLDP 310...
Page 322: ...322...
Page 334: ...Chapter 26 Software Configuration Updates 334...
Page 346: ...Chapter 28 Rebooting the AT GS950 16PS 346...
Page 368: ...Appendix A MSTP Overview 368...
Page 386: ...Appendix B AT GS950 16PS Default Parameters 386...