050 and Classic Line 075 Series Electric Models
Serial Plate Rating
Terminal Block
Connections Re-
quired
Serial Plate Amps
Recommended Circuit
Nonre-
versing
Revers-
ing
Breaker
Rating
Wire Size
AWG
[mm
2
]
240V/50Hz/1ph (050 Series
only)
L1, Neutral and Ground
93
95
125A – 1 pole
1 [35]
200-208V/60Hz/3ph
L1, L2, L3 and ground
89
88
125A – 3 pole
1 [35]
200V/50Hz/3ph
L1, L2, L3 and ground
84
85
125A – 3 pole
1 [35]
230V/50Hz/3ph
L1, L2, L3 and ground
73
75
100A – 3 pole
3 [26.7]
240V/50Hz/3ph
L1, L2, L3 and ground
79
78
100A – 3 pole
3 [26.7]
240V/60Hz/3ph
L1, L2, L3 and ground
79
78
100A – 3 pole
3 [26.7]
380V/50 or 60Hz/3ph
L1, L2, L3 and ground
47
48
60A – 3 pole
6 [16]
400-415V/50Hz/3ph
L1, L2, L3 and ground
43
44
60A – 3 pole
6 [16]
440V/60Hz/3ph
L1, L2, L3 and ground
41
41
50A – 3 pole
6 [16]
480V/60Hz/3ph
L1, L2, L3 and ground
38
38
50A – 3 pole
6 [16]
Table 11
Eco Line 075 Series Electric Models
Serial Plate Rating
Terminal Block Con-
nections Required
Serial Plate Amps
Recommended Circuit
Nonrevers-
ing
Revers-
ing
Breaker
Rating
Wire Size
AWG
[mm
2
]
200-208V/60Hz/3ph
L1, L2, L3 and ground
63
63
80A - 3 pole
4 [25]
240V/60Hz/3ph
L1, L2, L3 and ground
56
56
70A - 3 pole
4 [25]
380V/50Hz/3ph
L1, L2, L3 and ground
34.3
35.3
45A - 3 pole
8 [10]
380V/60Hz/3ph
L1, L2, L3 and ground
32.6
32.6
45A - 3 pole
8 [10]
400-415V/50Hz/3ph
L1, L2, L3 and ground
32.3
33.3
40A - 3 pole
8 [10]
440V/60Hz/3ph
L1, L2, L3 and ground
28.4
28.4
40A - 3 pole
8 [10]
460-480V/60Hz/3ph
L1, L2, L3 and ground
26.9
26.9
35A - 3 pole
8 [10]
Table 12
Electrical Requirements
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
61
Part No. 70457901ENR12
Summary of Contents for YU050E
Page 2: ......