![ALLIANCE YU050E Installation Operation & Maintenance Download Page 35](http://html.mh-extra.com/html/alliance/yu050e/yu050e_installation-operation-and-maintenance_2901132035.webp)
TMB2328N_SVG
4
3
2
1
1.
Gas Shut-Off Valve (Ahead of pressure tap) (Not Sup-
plied)
2.
Pressure Tap
3.
Gas Shut-Off Valve (Shown in closed position) (Not Sup-
plied)
4.
Specified Local Inlet Pressure
Figure 15
Specific Conversion Procedures
How to Convert Gas Valve from Regulated to Unregu-
lated
NOTE: Conversion from regulated to unregulated is on-
ly needed when regulated tumble dryers were ordered,
but unregulated tumble dryers were needed.
1.
Disconnect electrical power from tumble dryer. Close gas
shut-off valve to tumble dryer. Refer to
Figure 15
.
2.
Follow instructions in Conversion Kit, Part No. M400763.
NOTE: These kits do not contain any burner orifi-
ces.
3.
Replace burner orifice(s) as per
Table 1
4.
If applicable, peel off the appropriate conversion sticker (in-
cluded with machine) and apply it to the serial plate over the
“ADJUSTED FOR ______ GAS: ______” information.
5.
Commission tumble dryer for use.
How to Change Burner Orifice Size
1.
Disconnect electrical power from tumble dryer. Close gas
shut-off valve to tumble dryer. Refer to
Figure 15
.
2.
Remove spud holder. Unscrew spud holder nut near gas
valve. Remove the burner orifice(s) from spud holder. Refer
to
Figure 16
.
3.
Install the new, correct burner orifice(s). Refer to
Figure 17
and
Table 1
. Torque each to 9 – 10 Nm.
4.
Reinstall spud holder assembly to gas valve, making certain
burner orifice(s) are in line with burner tube opening. Refer to
Figure 17
.
5.
Commission tumble dryer for use.
NOTE: Blank burner orifices are Part No. M400995.
Installation
©
Copyright, Alliance Laundry Systems LLC -