Non-CE
and Non-
Australian
Models
Australian
and Kore-
an Models
CE Mod-
els
Recommend-
ed
11 in. w.c.
2.74 kPa
27.4 mbar
Minimum
10 in. w.c.
2.49 kPa
24.9 mbar
For converting Non-CE models from Natural Gas to L.P. Gas:
050 Series
M4979P3
075 Series
M4454P3
F75 Series
M4609P3
CE GASES refer to Installing CE Gas Drying Tumble Dryers
section, the above data does not apply to the CE.
Turn on gas and check all pipe connections (internal and exter-
nal) for gas leaks with a non-corrosive leak detection fluid. Purge
air in gas service line by operating the tumble dryers in the drying
mode. If burner does not light and unit goes into lockout, open
and close the door and restart. Repeat these steps until burner ig-
nites. Use pipe compound, resistant to actions of L.P. gas, on all
pipe threads.
WARNING
Check all pipe connections, internal and external, for
gas leaks using a non-corrosive leak detection fluid.
To reduce the risk of explosion or fire, DO NOT USE
AN OPEN FLAME TO CHECK FOR GAS LEAKS! Gas
connections should be checked twice a year for leak-
age.
W635
TMB2404N_SVG
6
3
4
5
1
2
1.
Gas Line to Tumble Dryer
2.
Gas Supply Piping System
3.
Gas "T" Fitting
4.
3 in. [76 mm] Minimum Gas Pipe
5.
Gas Pipe Cap
6.
Sediment Trap
Figure 22
Gas Requirements
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
43
Part No. 70457901ENR12