D696I_SVG
Figure 12
4.
Remove earth/ground screw save for use in Step 6. Remove
wire and use in Step 7.
D697_SVGI
1
1.
Ground Screw
Figure 13
5.
Use a strain relief and insert end of power cord through power
supply hole.
D698I_SVG
Figure 14
6.
Attach power cord earth/ground (green) wire to rear bulkhead
using earth/ground screw removed in Step 4.
DRY1920N_SVG
1
2
7
4
5
3
6
1.
White
2.
“L2” Terminal
3.
Black
4.
Green
5.
Red
6.
Neutral Terminal
7.
“L1” Terminal
Figure 15
7.
Use the three screws from the accessories bag to attach the re-
maining power cord wires to the terminal block as follows:
a. Red wire to “L1” terminal.
b. Black wire to “L2” terminal.
c. White wire to Neutral terminal.
NOTE: When installing the white wire, loop the free
eyelet end of the earth/ground to neutral wire (re-
moved in Step 4) and attach along with the white
wire to the neutral (center) terminal on the terminal
block.
8.
Tighten all screws firmly.
IMPORTANT: Failure to tighten these screws firmly
may result in wire failure at the terminal block.
9.
Check the continuity of the ground connection before plug-
ging the cord into an outlet. Use an acceptable indicating de-
vice connected to the center grounding pin of the plug and the
green screw on the back of the cabinet.
10.
Reinstall access cover and screw.
Reverse Door, if Desired
The door on this dryer is completely reversible. To reverse door
proceed as follows:
1.
Remove four hinge attaching screws.