Area
Description
Free Standing/Alcove In-
stallation
Closet Installation
A*
Dryer sides and rear clearance
0 in. [0 mm]
0 in. [0 mm]
B
Dryer top clearance
12 in. [305 mm]
12 in. [305 mm]
C
Dryer front clearance
Not Applicable
2 in. [51 mm]
D
Exhaust duct clearance to com-
bustible material
2 in. [51 mm]
2 in. [51 mm]
E
Weather hood to ground clear-
ance
12 in. [305 mm]
12 in. [305 mm]
F
Distance from floor or ceiling
to air opening edge
Not Applicable
3 in. [76 mm]
G
Area of centered air openings
in closet door. Louvered door
with equivalent air openings is
acceptable. (Minimum clearan-
ces are shown.)
Not Applicable
40 sq. in./open [260 sq. cm/
open]
H
For new installations, locate
top of wall vent 42 inches
[1067 mm] above floor to make
venting easier to connect.
42 in. [1067 mm]
42 in. [1067 mm]
*
Rear clearance is minimum. 2 inches [51 mm] is recommended for utility connection. 6 inches
[152 mm] is recommended when venting through rear of unit.
Table 1
NOTE: For new installations, locate top of wall vent 42
inches (106.7 cm) above floor to make venting easier to
connect.
IMPORTANT: In mobile home installations, gas dryers
MUST be permanently attached to the floor at the time
of installation. Order No. 526P3 Dryer Installation Kit
(available at extra cost) for a manufactured (mobile)
home installation. Follow the instructions supplied with
the kit.
Connect Dryer Exhaust System
WARNING
To reduce the risk of fire and the accumulation of
combustion gases, DO NOT exhaust dryer air into a
window well, gas vent, chimney or enclosed, unven-
tilated area, such as an attic, wall, ceiling, crawl
space under a building or concealed space of a
building.
W045
WARNING
A clothes dryer produces combustible lint. To re-
duce the risk of fire and combustion gas accumula-
tion the dryer MUST be exahusted to the outdoors.
W116
WARNING
This gas appliance contains or produces a chemical
or chemicals which can cause death or serious ill-
ness and which are known to the State of California
to cause cancer, birth defects, or other reproductive
harm. To reduce the risk from substances in the fuel
or from fuel combustion, make sure this appliance is
installed, operated, and maintained according to the
instructions in this manual.
W115
Installation
Part No. 510963R7
©