2.
Close the loading door and start the dryer in a heat setting (re-
fer to the operation instructions). The dryer will start, the ig-
niter will glow red and the main burner will ignite.
IMPORTANT: If all air is not purged out of gas line,
gas igniter may go off before gas is ignited. If this
happens, after approximately two minutes igniter
will again attempt gas ignition.
3.
After the dryer has operated for approximately five minutes,
observe burner flame through lower front panel.
4.
Adjust the air shutter to obtain a soft, uniform blue flame. (A
lazy, yellow-tipped flame indicates lack of air. A harsh, roar-
ing, very blue flame indicates too much air.) Adjust the air
shutter as follows:
a. Loosen the air shutter lockscrew.
b. Turn the air shutter to the left to get a luminous yellow-
tipped flame, then turn it back slowly to the right to obtain
a steady, soft blue flame.
c. After the air shutter is adjusted for proper flame, tighten
the air shutter lockscrew securely.
5.
Reinstall the lower front panel.
WARNING
For personal safety, lower front panel must be in
place during normal operation.
W046
6.
After the dryer has operated for approximately three minutes,
exhaust air or exhaust pipe should be warm.
D702I_SVG
4
1
2
3
1.
Air Shutter Lockscrew
2.
Appliance Main Gas Valve
3.
Air Shutter
4.
1/8 in. [3.1 mm] Pipe Plug (For checking manifold pres-
sure)
Figure 28
Installation
Part No. 510963R7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
21
Summary of Contents for Dryers