To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be reconnected
to ensure that the dryer is properly grounded.
WARNING
W001R1
505038
53
Figure 48
i. Front Cylinder Seal (Figure 48)
When installing the cylinder seal, it is important
to remember these two important steps:
(1) The stitching on the seal must face towards
center of dryer.
(2) The short flap must be glued to the bulkhead
and the long flap left loose.
IMPORTANT: The replacement seal can be adhered
to the bulkhead using No. 22506P Sealant. This is
accomplished by applying a bead of sealant around
the entire flanged area where the felt seal contacts the
bulkhead.
BULKHEAD
LONG FLAP
SEAL STITCHING
(Must face towards
center of dryer)
SHORT FLAP
(Must be glued
to bulkhead)
D257SE3A