To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be reconnected
to ensure that the dryer is properly grounded.
WARNING
W001R1
44
505038
35. DOOR HINGE (Figure 34)
a. Open loading door and, while supporting door,
remove four screws holding door assembly to
hinges.
b. Remove four screws holding hinges to front
panel.
36. HOLD-DOWN CLIPS AND LOCATORS
(Figure 33)
a. While supporting the access panel, remove two
screws from bottom edge of access panel. See
Figure 4.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel.
c. Remove two screws holding bottom tabs on front
panel to dryer side panels. Swing bottom edge of
front panel away from dryer far enough to
disengage hold-down clips and locators from
cabinet top.
d. Disconnect wires from door switch. See
Figure 32.
NOTE: Refer to appropriate wiring diagram when
rewiring switch.
Figure 34
LINT FILTER
ATTACHING
SCREW
LINT
FILTER
D306SE3B
DOOR
HINGES
DOOR
ATTACHING
SCREWS
LINT
FILTER