To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be reconnected
to ensure that the dryer is properly grounded.
WARNING
W001R1
505038
47
38. BURNER HOUSING AND HEAT SHROUD
(Gas Models)
a. While supporting the access panel, remove two
screws from bottom edge of access panel. See
Figure 4.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. See
Figure 33.
c. Disconnect igniter wires at disconnect blocks,
sensor wires from flame sensor terminals, and
wires from gas valve coils at the quick disconnect
blocks. See Figure 35.
d. Remove screw from right side of burner housing,
while holding burner tube in place. See Figure 37.
e. Gently move burner tube toward rear of dryer to
disengage tab from slot on left side of burner
housing. See Figure 35.
f. Carefully rotate burner tube and igniter
counterclockwise so tab is at 8 o’clock position.
g. Move air shutter end of burner tube slightly to the
right and CAREFULLY remove burner tube and
igniter assembly out through front of dryer.
IMPORTANT: The igniter is very fragile. Be careful
not to damage it during removal.
h. Remove screw holding burner housing to heat
shroud. See Figure 35.
i. Remove screw holding front of burner housing to
dryer base and remove housing out through front
of dryer. See Figure 37.
j. Remove two screws holding heat shroud to heater
box and take heat shroud out through front of
dryer.
39. LIMIT THERMOSTAT
a. While supporting the access panel, remove two
screws from bottom edge of access panel. See
Figure 4.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. See
Figure 33.
c. Disconnect wires and remove screws holding
limit thermostat to burner housing (gas models) or
element plate (electric models). See Figure 37.
40. HEATING ELEMENT (Electric Models)
a. While supporting the access panel, remove two
screws from bottom edge of access panel. See
Figure 4.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. See
Figure 33.
c. Remove two screws holding element and plate to
heater box and remove element and plate out
through front of dryer. See Figure 37.
d. Disconnect wires from element and plate. See
Figure 37.
NOTE: When reassembling, be sure all wire
connectors are tight on element terminals, thermal
fuse and limit thermostat.
ELECTRIC MODELS
GAS MODELS
Figure 37
HEATER
ASSEMBLY
HEATER WIRE
CONNECTIONS
LIMIT
THERMOSTAT
THERMAL
FUSE
SCREW
D243SE3A
LIMIT
THERMOSTAT
BURNER
TUBE
SCREW
BURNER TUBE
SCREW
GAS VALVE
HANDLE
(Shown in Closed
Position)
BASE
BURNER
HOUSING
D244SE3B