To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be reconnected
to ensure that the dryer is properly grounded.
WARNING
W001R1
34
505038
24. COIN DROP
a. Removal
(1) Unlock control panel. See Figure 5A.
(2) Pull top of control panel away from control
cabinet and lift up. See Figure 5B.
(3) Remove control panel from control cabinet.
See Figure 5C.
(4) Disconnect all wires from control panel
components. See Figure 6.
(5) Remove ground clip holding ground wire to
control panel. See Figure 6.
NOTE: Refer to appropriate wiring diagram when
reconnecting wires.
(6) Reach into control cabinet to feel position of
coin drop. Disconnect coin drop harness at
disconnect plug. See Figure 18.
(7) Use a 3/8 inch square drive 7/16" socket with
No. 310P4 1/4 inch Ratchet Extension Tool
to remove two locknuts holding coin drop to
front of control cabinet. See Figure 19.
NOTE: A 3/8 inch square drive socket, size 7/16", fits
over the end of the 310P4 extension tool. A 1/4 inch
ratchet fits in the other end.
Figure 18
25¢
25¢
CONTROL
CABINET
D343SE3A
DISCONNECT
PLUGS
COIN
DROP
Figure 19
25¢
25¢
1/4"
RATCHET
D344SE1A
FRONT OF
CONTROL
CABINET
LOCKNUT
3/8 INCH
SQUARE DRIVE
7/16" SOCKET
NO. 310P4
1/4" RATCHET
EXTENSION