![Alliance Laundry Systems HTEB17-N2802 Service Manual Download Page 40](http://html.mh-extra.com/html/alliance-laundry-systems/hteb17-n2802/hteb17-n2802_service-manual_2901655040.webp)
38
801774
Section 3 Troubleshooting (NetMaster and MDC Models – Washer Control)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
28. SERIAL COMMUNICATION ERROR (E:SP ON WASHER DISPLAY)
S
ERIAL COMMUNICATION ERROR (E:
S
P on display
Restart
machine and
check voltage: Is
there 220-240 VAC (or
120 VAC)* across terminals
"H1-1" and "H1-
3
"
on motor
control?**
Replace
electronic
control.
Tighten fuse
holder and/or
replace fuse.
No
No
Yes
(2)
(1)
(
3
)
(4)
No
Correct wiring from
electronic control to
motor control.
Is there
continuity through
each wire of the harness
from H2 on the electronic
control to H7 on the
motor control?
Yes
Change the
motor control.
Change the
harness.
Restart
machine and
check voltage: Is
there 220-240 VAC (or
120 VAC)* across terminals
"H6-5" and "H6-6"
on the electronic
control?**
Is the fuse loose or
blown on the motor
control board?
Yes
No
Yes
FLW1701S
*Refer to machine serial plate for correct voltage.
**NOTE: Machine must be restarted to check voltage.
Voltage will be intermittently present during first 15
seconds until E:
S
P is displayed.
1
2
4
3
Summary of Contents for HTEB17-N2802
Page 2: ......
Page 6: ...4 801774 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Page 12: ...10 801774 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Page 16: ...14 801774 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Page 48: ...46 801774 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Page 64: ...62 801774 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Page 78: ...76 801774 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Page 180: ...178 801774 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...