Error Codes
Display
Description
Cause/Corrective Action
E d 51
Inrush Pin HW
On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 52
Voltage Doubler
Pin HW On/Off
Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 53
Door Lock Select
Voltage Pin HW
On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 54
Pump Pin HW
On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 55
Fatal NTC Short
Error
Check heater thermistor and thermistor wiring for damage. Unpower to clear error.
Replace drive board if error persists.
E d 56
Fatal NTC Open
Error
Check heater thermistor and thermistor wiring for damage. Unpower to clear error.
Replace drive board if error persists.
E d 63
Fatal IPM Temper-
ature Short Error
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 64
Fatal IPM Temper-
ature Open Error
Hardware failure. Unpower to clear error. Replace drive board if error persists.