Machine Cleaning Procedure
When cleaning the machine, please adhere to the following information to ensure proper cleaning and to
keep the machine in the best condition possible.
Power Washing Procedure:
• Ensure that the water pressure is below 2000 PSI (14 MPa)
• Always keep the water temperature below 180°F (80°C)
• Use a spray nozzle with at minimum 40° wide spray angle
• Keep the nozzle at least 1 foot (300mm) away from the machine
• Keep a perpendicular angle (90°) when cleaning over a decal.
- Holding nozzle of a pressure washer at an angle different from 90° may lift the
decal from the machine.
• Recommended using a safe cement dissolver,
BACK-SET
or similar
,
to remove
hardened concrete.
• It is
NOT
recommended to use chemicals such as:
- Muriatic Acid
- Hydrochloric Acid
- Hydrofluoric Acid
- Sulfuric Acid
- Phosphoric Acid
• To prevent build-up of concrete on the machine, use
BODY GUARD
or similar protection wax.
Filter Cleaning Procedure:
• Remove air filters and blow out with compressed air,
NOT
to exceed 80 PSI.
Cleaning Procedure
SECTION 3
SERVICE
069970
Page 54
Summary of Contents for 068360
Page 12: ...SECTION 1 SAFETY SECTION 1 SAFETY 069970 Page 12 ...
Page 25: ...SECTION 2 OPERATION SECTION 2 OPERATIONS 069970 Page 25 ...
Page 37: ...SECTION 3 SERVICE 069970 Page 37 SECTION 3 SERVICE ...
Page 55: ...SECTION 4 ACCESSORIES SECTION 4 ACCESSORIES 069970 Page 55 ...
Page 59: ...069970 Page 59 ...