Fault Codes
SPN
Code
FMI
Code
Fault Check Description
Fault Detection Condition
Possible
Causes
190
2
DFC for camshaft offset angle exceeded
DFC for camshaft offset angle exceeded
Wiring Harness or
Camshaft Sensor
Defect or Wrong
Mounting Position
or Tone Wheel
Mis-adjusted
8
In between of several camshaft revo-
lutions there are too many or too less
camshaft edges present or the distance
or the series of the camshaft edges is
unplausible. The defect debounce count-
er EpmCaS_ctErrSigDef is incremented
at each inplausible camshaft revolution,
reaches the counter the threshold
EpmCaS_numErrSigDef_C the error is
set. If the monitoring range is left, the
debounce counter is reseted.
In between of several camshaft revolutions there are too many or too
less camshaft edges present or the distance or the series of the cam-
shaft edges is unplausible. The defect debounce counter EpmCaS_ctErr-
SigDef is incremented at each inplausible camshaft revolution, reaches
the counter the threshold EpmCaS_numErrSigDef_C the error is set. If
the monitoring range is left, the debounce counter is reseted.
Tone Wheel
Defective
12
In between of several crankshaft revo-
lutions there is not any camshaft edge
present. The defect debounce counter
EpmCaS_ctNoSig reaches the thresh-
old EpmCaS_numNoSigDef_C. If the
monitoring range is left, the debounce
counter is reseted.
In between of several crankshaft revolutions there is not any camshaft
edge present. The defect debounce counter EpmCaS_ctNoSig reaches
the threshold EpmCaS_numNoSigDef_C. If the monitoring range is left,
the debounce counter is reseted.
Wiring Harness or
Component
652
3
General Short Circuit
Short Circuit of an Injector
Wiring Harness or
Injector Cylinder
653
3
5
Open Load
Open Load Error of an Injector (Interruption of an electric connection)
Wiring Harness or
Injector Load Drop
Cylinder
654
3
General Short Circuit
Short Circuit of an Injector
Wiring Harness or
Injector Cylinder
5
Open Load
Open Load Error of an Injector (interruption of an electric connection)
Wiring Harness or
Injector Load Drop
Cylinder
677
3
Short Circuit to Battery Error
Wiring Harness or
Component
4
Short Circuit to Ground Error
5
No Load Error
6
Over Temperature Error on ECU Power-
stage for Starter
Over Temperature
Error on ECU
Power-stage for
Starter
976
2
Diagnostic fault check non plausibility of
COM message
The sensed raw value PTOSwt_uSens is less than the minimum thresh-
old MoFPTO_uThresCalMsgA[n] or PTOSwt_uSens is more than the
maximum threshold MoFPTO_uThresCalMsgA[n+1] (wherein n=0,2,4,6),
whenever MoFPTO_swtSigSelCalMsg is equal to 0.
Wiring Harness or
Component
3
Diagnostic fault check for max error of
COM message
The sensed raw value PTOSwt_uRaw is more than PTOSwt_SRC.uMax_C
when MoFPTO_swtSigSelCalMsg is equal to 0.
4
Diagnostic fault check for min error of
COM message
The sensed raw value PTOSwt_uRaw is less than PTOSwt_SRC.uMin_C
when MoFPTO_swtSigSelCalMsg is equal to 0.
SECTION 3
SERVICE
069970
Page 45
Summary of Contents for 068360
Page 12: ...SECTION 1 SAFETY SECTION 1 SAFETY 069970 Page 12 ...
Page 25: ...SECTION 2 OPERATION SECTION 2 OPERATIONS 069970 Page 25 ...
Page 37: ...SECTION 3 SERVICE 069970 Page 37 SECTION 3 SERVICE ...
Page 55: ...SECTION 4 ACCESSORIES SECTION 4 ACCESSORIES 069970 Page 55 ...
Page 59: ...069970 Page 59 ...