Fault Codes
SPN
Code
FMI
Code
Fault Check Description
Fault Detection Condition
Possible
Causes
105
0
Physical Range Check high for Charged
Air cooler down stream temperature
Physical Range
Check high for
Charged Air cooler
down stream
temperature
1
Physical Range Check low for Charged
Air cooler down stream temperature
3
The sensor raw signal Air_uRawTCACDs
(voltage) is above Air_SRCTCACDs.
uMax_C (4803mV).
The sensor raw signal Air_uRawTCACDs (voltage) is above Air_SRCT-
CACDs.uMax_C (4803mV).
wiring harness or
component
4
The sensor raw signal Air_uRawTCACDs
(voltage) is above Air_SRCTCACDs.
uMax_C (318mV).
The sensor raw signal Air_uRawTCACDs (voltage) is above Air_SRCT-
CACDs.uMax_C (318mV).
107
3
SRC High for Controller Mode Switch
Wiring Harness or
Component
4
SRC Low for Controller Mode Switch
Wiring Harness or
Component
14
Error Path for Clog Detection in Air Filter
Air Filter Clogged
/ Sensor Value
Okay?
108
0
Ambient Air Pressure Sensor Range
Check Max-Error
Wiring Harness or
Component
1
Ambient Air Pressure Sensor Range
Check Min-Error
3
Fault Check Max Signal Range Violated
for Ambient Air Pressure Sensor
4
Fault Check Min Signal Range Violated
for Ambient Air Pressure Sensor
110
0
Physical Range Check High for CEngDsT
The sensed sensor signal CEngDsT_tSens is greater than CEngDsT_
PhysRng.Max_C
1
Physical Range Check Low for CEenDst
The sensed sensor signal CEngDsT_tSens is less than CEngDsT_Phys-
Rng.Min_C
3
The Sensor Raw Signal: CEngDst_uRaw
(Voltage) is Above CEngDst_SRC.uMa-
x_C (4957mV)
The sensor raw signal CEngDsT_uRaw (voltage) is above CEngDsT_SRC.
uMax_C.
4
The Sensor Raw Signal: CEngDst_uRaw
(Voltage) is Below CEngDst_SRC.uMin_C
(359mV)
The sensed raw voltage value CEngDsT_uRaw is less than CEngDsT_
SRC.uMin_C.
15
Engine Coolant Temp Too High
Plausibility Error
An “ERROR” is reported if the engine coolant temperature CEngDsT_t is
greater than an threshold CEngDsT_tMaxT_C.
Less Cooling
Water, Water
Pump Defective,
Water Cooler
Blocked
17
Defect Fault Check for Absolute
Plausibility Test
coolant temperature did not reach the threshold temperature
Sensor Value
Problem
18
Defect Fault Check for Dynamic
Plausibility Test
rise in coolant is not reached the minimum rise of coolant temperature
111
17
Low Coolant Level Error
If the Coolant Level is Low, i.e. if the message ClntLv_st is set.
Lowe Coolant
Level; Coolant
Level Sensor
Defective; Wiring
Harness Defective
SECTION 3
SERVICE
069970
Page 43
Summary of Contents for 068360
Page 12: ...SECTION 1 SAFETY SECTION 1 SAFETY 069970 Page 12 ...
Page 25: ...SECTION 2 OPERATION SECTION 2 OPERATIONS 069970 Page 25 ...
Page 37: ...SECTION 3 SERVICE 069970 Page 37 SECTION 3 SERVICE ...
Page 55: ...SECTION 4 ACCESSORIES SECTION 4 ACCESSORIES 069970 Page 55 ...
Page 59: ...069970 Page 59 ...