7.
MIDI Sustain Kick Switch
(optional)
A lever located to the left of the expression shoe and controlled by the organist’s foot,
operates MIDI sustain. This function can be assigned to any one of or all of the instrument’s
manuals.
To access the MIDI Sustain selection display, touch:
OPTIONS >> MIDI >> SUSTAIN
Touch the associated manual’s button to change the on
or off status. The function will “toggle” each time the
button is touched. If a manual button is highlighted,
the Sustain function is “on”. If a manual button is not
highlighted, the Sustain function is “off”.
OFF
will not allow MIDI Sustain messages to be
transmitted,
ON
will allow MIDI sustain messages to
be transmitted on a given keyboard (manual) or MIDI
channel. For example, when a
PIANO
voice in an
external MIDI device (voice module) is selected and the MIDI sustain for that given MIDI
channel (division) is turned
ON
, and the foot controlled sustain lever is actuated, the piano
sound will slowly decay.
Touch the HOME button to return to the
Home
screen or the BACK button to return to the
previous menu screen.
8.
Organ Local Off
Organ Local Off is a function that will “virtually” disconnect the organ’s keyboards,
pedalboard and pistons from the organ’s tone generation and capture system. In essence, the
organ is transformed into a sophisticated multi-manual MIDI controller.
To access the Organ Local Off function, touch:
OPTIONS >> MIDI >> ORGAN LOCAL OFF
To
enable
the Organ Local Off function, touch the
ENABLE button to highlight it.
To
disable
the Organ Local Off function, touch the
DISABLED button to highlight it.
Note:
When Organ Local Off is enabled, the MIDI
stops do not need to be turned on to play the external
MIDI device(s).
Touch the HOME button to return to the
Home
screen or the BACK button to return to the
previous menu screen.
10.
Transmission/Reception of Individual Stop Data
This function allows the organist to turn on/off the transmission and reception of individual
stop data, known in MIDI terminology as "Non-Registered Parameters". In some cases
individual stop data (on/off) from the organ may conflict with data from an external MIDI
device. When this occurs, select "OFF".
Note:
Piston changes will still be transmitted and received, because they are MIDI program
changes.
Note:
This function always defaults to “on” whenever the organ is turned on.
33