14
Rockwell Automation Publication PFLEX-AP005B-EN-P - May 2019
Chapter 1
Drive Selection Considerations
Table 7 - PowerFlex 700 Drive to PowerFlex 750-Series Drive Conversions
TIP
Voltage rating is 240V AC for all the drives that are listed.
PowerFlex 700 Drive
(1)
PowerFlex 750-Series Drive Conversion
(2)
20B
Amps
HP
(ND)
Frame
Height
mm,
(in.)
Width
mm,
(in.)
Depth
mm,
(in.)
20F/
20G
Amps
HP
(ND)
Frame
Height
mm,
(in.)
Width
mm,
(in.)
Depth
mm,
(in.)
2P2
2.2
0.5
0
336
(13.22)
110
(4.33)
200
(7.87)
2P2
2.2
0.5
2
424.2
(16.7)
134.5
(5.29)
212
(8.34)
4P2
4.2
1.0
0
4P2
4.2
1.0
2
6P8
6.8
2.0
1
135
(5.31)
6P8
6.8
2.0
2
9P6
9.6
3.0
1
9P6
9.6
3.0
2
015
15.3
5.0
1
015
15.3
5.0
2
022
22
7.5
1
022
22
7.5
2
028
28
10
2
342.5
(13.48)
222
(8.74)
028
28
10
3
454
(17.87)
190
(7.48)
042
42
15
3
517.5
(20.37)
042
42
15
3
052
52
20
3
054
54
20
4
474
(18.66)
222
(8.74)
070
70
25
4
759
(29.88)
220
(8.66)
202
(7.95)
070
70
25
5
555
(21.85)
270
(10.62)
080
80
30
4
080
80
30
5
104
104
40
5
644.5
(25.37)
309
(12.16)
275.5
(10.84)
104
104
40
6
665.5
(26.2)
308
(12.12)
346.4
(13.63)
130
130
50
5
130
130
50
6
154
154
60
6
850
(33.46)
(3
)
404
(15.9)
154
154
60
6
192
192
75
6
192
192
75
6
260
260
100
6
260
260
100
6
(1) All dimensions are IP20, NEMA/UL Type 1 unless specified otherwise.
(2) All dimensions are IP20, NEMA/UL Open type unless specified otherwise.
(3) Height dimension shown for a drive mounted in a cabinet; height dimension is 976.5 mm (38.4 in.) with required junction box if not cabinet-mounted.