24
Rockwell Automation Publication 20B-IN019E-EN-P - July 2013
PowerFlex 700 Adjustable Frequency AC Drive – Frames 0…6
Single-Phase Input Power
The PowerFlex 700 drive is typically used with a three-phase input supply. Single-
phase operation is possible with output current derated by 50% (at maximum
ambient temperature of 25 °C) of the three-phase ratings. Refer to tables
4
through
6
.
AC Input Phase Selection (Frames 5…6 Only)
Moving the “Line Type” jumper on the Precharge Board (see below) allows single
or three-phase operation.
Typical Location - Phase Select Jumper
Table 4 - 208/240 Volt Single-Phase AC Input Ratings
ATTENTION:
To avoid a shock hazard, ensure that all power to the drive has
been removed before performing the following.
IMPORTANT
When selecting single-phase operation, input power must be applied to the
R (L1) and S (L2) terminals. This ensures that the fan is properly powered.
240V Single-Phase AC Input
208V Single-Phase AC Input
Temp.
Drive
Catalog
Number
Fram
e Hp
Rating
Input
Amps
Three-Phase
Output
Drive
Catalog
Number
Fram
e Hp
Rating
Input
Amps
Three-Phase
Output
V AC
Amps
V AC
Amps
°C
20BB2P2
0
0.25
1.5
0-230
1.1
20BB2P2
0
0.25
1.7
0-200
1.3
25
20BB4P2
0
0.5
2.8
0-230
2.1
20BB4P2
0
0.5
3.2
0-200
2.4
25
20BB6P8
1
1
5.1
0-230
3.4
20BB6P8
1
1
5.9
0-200
3.9
25
20BB9P6
1
1.5
7.2
0-230
4.8
20BB9P6
1
1.5
8.3
0-200
5.5
25
20BB015
1
2.5
11.9
0-230
7.7
20BB015
1
2.5
13.6
0-200
8.8
25
20BB022
1
3.75
17.3
0-230
11
20BB022
1
3.75
19.9
0-200
12.7
25
20BB028
2
5
22.2
0-230
14
20BB028
2
5
25.7
0-200
16.1
25
20BB042
3
7.5
33.4
0-230
21
20BB042
3
7.5
38.5
0-200
24.2
25
20BB052
3
10
41.3
0-230
26
20BB052
3
10
44.6
0-200
28
25
20BB070
4
12.5
55.6
0-230
35
20BB070
4
12.5
62.3
0-200
39.1
25
20BB080
4
15
63.6
0-230
40
20BB080
4
15
73.3
0-200
46
25
20BB104
5
20
84.6
0-230
52
20BB104
5
20
97.9
0-200
60
25
20BB130
5
25
105.7
0-230
65
20BB130
5
25
106.1
0-200
65
25
20BB154
6
30
125.2
0-230
77
20BB154
6
30
144.4
0-200
88.5
25
20BB192
6
37.5
156.1
0-230
96
20BB192
6
37.5
180.3
0-200
110.5
25
20BB260
6
50
211.4
0-230
130
20BB260
6
50
212.1
0-200
130
25
LINE
TYPE
SPARE 1
SPARE 2
3-PH 1-PH
JP1
JP2
JP3
1-PH 3-PH
LINE T
YPE
3
3
3
AC Input
Precharge
Board