17–28
Communicating with PanelView 900
Terminals on a DeviceNet Network
Publication 2755-6.8
Read Package Counter Tag Configuration
AdaptaScan can keep a count of how many times it was triggered or
asked to read a bar code. The dialog box for the package count
numeric display object is shown below.
The PanelView will display six digits of the Package count value, the
package count from the AdaptaScan can be up to ten digits. By
selecting the Edit Tag option, you can edit the tag data as shown
below.
The data type is Unsigned Integer. The data type should be changed
to Signed Integer. The Class, Instance and Attribute are set to read
the AdaptaScan package count.
Note: Use the Print function of the AdaptaScan software to print
application data. The report will provide you with the DeviceNet
Class and Instance values for the configuration data.