11–12
Communicating with a PLC-5 Processor on a DeviceNet Network
Publication 2755-6.8
This section shows how to configure the AdaptaScan Bar Code
Reader using AdaptaScan Software (Catalog No. 2755-ASN).
The procedures in this section show how to:
•
scan/decode 4 character, Interleaved 2 of 5 labels
•
define a DeviceNet address
•
configure the scanner
•
configure the decoder trigger
•
configure the format of messages and the message destination
Create a New Project
Create a new project named PLC DeviceNet for one AdaptaScan Bar
Code Reader (Bar Code Reader 1).
1. Choose New from the Project menu to create a new project.
2. Click the New button to add a bar code reader (Bar Code Reader
1) to the project.
3. Choose Edit from the Project menu to rename the project PLC
DeviceNet.
If you need to change the baud rate, proceed to the next section.
If you do not need to change the baud rate, proceed to step 4.
Configuring the Reader