Appendix A
Configure Modules in RSLogix 5000 Software
Work with the Conversion
Dialog
Follow these procedures to complete entries for the Conversion dialog.
1.
From the General dialog, click Conversion to display the Conversion
dialog.
2.
From the Conversion dialog, complete entries, referring to the table.
3.
From the Conversion dialog, complete one of these.
•
Click OK to save changes and close the dialog.
or
•
Click Cancel to return to default values.
or
•
Click Apply to save changes you made on any of the dialogs and
continue to display the dialog, noting that you enable the Apply button
when you make changes to any of the dialogs.
or
•
Click another tab at the top of dialog.
For more information on these parameters, refer to the definitions in Chapter 4
of this publication.
For
Select
Comments
Gray-to-Binary Convert
Click the checkbox
Default is no Gray-to-binary convert with the checkbox
not checked.
Standardization
Click the checkbox
Default is no standardization with the checkbox not
checked.
Trailing Bits
0...16
When you check Standardization, Trailing Bits is
selectable.
Default is 0.
Sensor Resolution
1...65535
Default is 1.
Sensor Cycles
1...65535
Default is 1.