background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CITY POOL Installation and Maintenance  

Guide  

 

 

Summary of Contents for CITYPOOL

Page 1: ...CITY POOL Installation and Maintenance Guide...

Page 2: ...e swimming pool partly or minimally or even for very short time please follow recommended precautions or contact your distributor Do not use products which were not recommended by your distributor esp...

Page 3: ...ow of the pool filling with rubble 16 7 2 Corners filling 18 7 3 Filling with earth halfway 19 7 3 Pump room filling 19 9 Concrete protective fencing 20 CONNECTION OF TECHNOLOGICAL POOL EQUIPMENT 22 1...

Page 4: ...4 23 Pool water drainage 40 24 Pool maintenance during the winter season 40 POSSIBLE PROBLEMS AND THEIR SOLUTION IN THE OPERATION OF THE POOL 41...

Page 5: ...rding to the lenght 3 cm c The square according different diagonals acceptable tolerance 5 mm to meter Pool Walls and Bottom tolerances a at the water line 2cm maximum deviation for walls 2m long 5mm...

Page 6: ...hem in the installation agreement documentation signed and stamped by both parties client and contractor Make sure that there is no gas electricity telephone irrigation or drainage network on the site...

Page 7: ...rk the dot 1 5 meters from the corner on the short edge of the pool measure the distance between the 2 aided points it should be 2 5 meters repeat the marking if larger Triangle diagonal the square ro...

Page 8: ...the rapid removal of filtered water rain water or ground water It is very important at the bottom of the hole where the swimming pool is set to install one or more drainage balance wells together wit...

Page 9: ...unities allow it can also be laid with a larger slope It is advisable to make an infusion of rubble with a fraction not exceeding 32 mm around the pipe Water permeable soil must be poured over the rub...

Page 10: ...10 Fig 5b The first phase of earthworks Drainage installation Fig 5c The first phase of earthworks Drainage installation...

Page 11: ...he height by keeping optical reference point as zero point plus 1 37 m depth as shown f Fill the crushed stone to the level indicated in Fig 5 An average rubble thickness of about 20 cm is recommended...

Page 12: ...quipment requirements to be sure they are correct for the particular pool installation To unload pool is necessary to have straps vith hooks and chains The swimming pool will be lowered gently into th...

Page 13: ...surface make sure that the pool does not deviate from the axes in the soil which you established Fig 13 Pool positioning by axis If a difference in level appears do not apply pressure and jump on the...

Page 14: ...14 Fig 14a The second phase of earthworks Pool positioning Fig 14b The second phase of earthworks Pool positioning...

Page 15: ...the water filling inlet in it and then filling the pool and the addition will be easy for you to adjust with the valve installed in a convenient location Skimmer overflow outlet connection 1 The skim...

Page 16: ...he basin is completely filled Fig 15 Pool fixing with supports and straps 2 Once the pool is anchored add 20 cm of water and once again check that the pool level is in correct possition Fill the pool...

Page 17: ...17 Fig 16 Pool fixing with supports and straps Fig 17 Pool filling with rubble...

Page 18: ...eserve the stability of the structure it is recommended to use of light machinery for filling process mini loader type Check level and readjust swimming pool leveling To lower an angle do not tap your...

Page 19: ...d the hull The water must not exceed the level of crushed stone The wall of the pool must not be enclosed either exterior or interior Constantly compact filling earths with grip or tube until earth le...

Page 20: ...ixed concrete will be required Class C25 30 M350 Concrete can be made locally with a concrete mixer C 365kg cement M400 S 550kg of sand fraction 1 3 3 5mm G 1100kg of gravel granite crushed stone frac...

Page 21: ...e install an expansion joint between the pool edge beam and the support slab Attention Constantly monitor that the point 0 is above the natural soil level around the pool Also drain rainwater to preve...

Page 22: ...22 CONNECTION OF TECHNOLOGICAL POOL EQUIPMENT 11 Pool equipment 11 1 BASIC modification...

Page 23: ...23 Fig 26 City Pool Basic schematic diagram...

Page 24: ...D light with stainless steel cover 3 4 Inlet Jet with stainless steel cover 4 5 Pump room drain for condensate drainage ABS with plug and grille 5 6 Hayward Powerline P 0 38kW Q 5 4m3 h 8m centrifugal...

Page 25: ...25 11 2 ACTIVE modification...

Page 26: ...26 Fig 27 City Pool Active schematic diagram...

Page 27: ...m Jet adjustable counterswim jet with with stainless steel cover 4 5 Pump room drain for condensate drainage ABS with plug and grille 5 6 Waterway suction 6 7 Piezo switch for LED light 7 8 Piezo swit...

Page 28: ...28 11 3 FUN modification...

Page 29: ...drain at the bottom with plug and grille ABS 2 3 LED light with stainless steel cover 3 4 Waterway Swim Jet adjustable counterswim Jet with with stainless steel cover 4 5 Pump room drain for condensat...

Page 30: ...ng 9 10 Two speed centrifugal pump P 0 43 2 38kW 230V Qmax 45m3 h M1 11 Electrical Control Panel single phase 40A 230V CP 12 Pipening with valves slice valve adjustable valve S1 S2 S3 S4 13 Motorized...

Page 31: ...connection schematic diagram Electric heater Balboa 3kW 230V Digital thermostat NA8810 230V 20A TH REMEMBER Heating is posible when the pool water is circulating 3kW heater raises pool water temperat...

Page 32: ...the setting value will not be saved Advanced Operation Press the key M and hold it for 5 seconds and if you have set the password the LED display the PAS to hint you to enter the password you can use...

Page 33: ...of the by pass line d63 d50 Install shut off valves at the heat pump IN and Out It is also necessary to connect a dry contact from the electrical control panel CP to control the heat pump The heat pum...

Page 34: ...3 250 V AC City Pool Active bei City Pool Fun models cable min 3x2 5mm and circuit breaker 20A C20 250 V AC The recommended diameter of the power cable is up to 30m from the common panel In any case i...

Page 35: ...oating on the surface of the water and is trapped in cartridge filters From the skimmer the water flows through the pipeline to the circulation pump M1 and is then returned to the pool via the nozzles...

Page 36: ...S7 so that some of the water could circulate through the heat pump valve S7 is for throttling 7 Leave the Pump room drain open for drainage 8 Turn on the circuit breakers on the electrical control pan...

Page 37: ...e without regular maintenance It is important the water hardness so that the bearings do not get lime deposits If the nozzles become clogged they must be dismantled cleaned and returned to the socket...

Page 38: ...necessary 7 Inspection of drainage system Well The water level of the drainage Well must be checked periodically Check that the submersible pump is not blocked 18 Cleaning and replacing cartridge filt...

Page 39: ...r pH values above 7 4 pH minus is required for pH values below 7 0 pH plus is required Combating algae Algicides prevent the algae from getting established and multiplying in the pool Algae that have...

Page 40: ...d pets from accidentally getting into the pool 23 Pool water drainage IMPORTANT Draining water from the pool can only be done with the supervision or consultation of the company that installed the poo...

Page 41: ...ir which returns to the pool through the nozzles Add water to the pool Foam appears when using massage equipment A non foaming algicide is required to prevent foaming The water changed color and turne...

Page 42: ......

Page 43: ...43...