24
23
THREE-BUTTON STATION CONNECTION
N.C.
N.O.
N.O.
COM
STOP CMD JUMPER
ON SL-100 AC MODEL
(REMOVE IF 3 BUTTON
STATION IS INSTALLED)
BOARD TERMINAL STRIP
OPEN
CLOSE
STOP
Ÿ
A three button station and reset push button are integrated on the board to make limit and ERD adjustments
easier.
Ÿ
An external three button station may also be installed. See diagram below for wiring instructions,
Ÿ
NOTE:
On SL-100 AC model,
STOP CMD
jumper must be removed if a three button station is installed.
Push
Button
Contacts
Terminals
Open
Common
Normally Open
24V-COM
EXIT/OPEN_CMD
Close
Common
Normally Open
24V-COM
CLOSE_CMD
Stop
Common
Normally Closed
24V-COM
STOP_CMD
MASTER/SLAVE CONNECTION
BEFORE CONNECTING MASTER/SLAVE COMMUNICATION WIRES, TAKE THE FOLLOWING STEPS:
1: Test and adjust the limit switches and ERDs for each operator as stand alone machines.
2: Once the machines have been adjusted, turn slave dip switch “ON” on the slave board.
Press the RESET button on the slave board or reset the power.
3: Connect the master/slave communication wires to “DATA -” and “DATA +”.
The “M/S LINK” LED should be “ON” on both machines.
4: Connect all accessories to the master operator. Accessories installed on the slave operator will not work.
(Note: Accessory power may be connected to the slave operator, but relay wires must be connected on
the master operator.)
.
1 2 3 4 5 6 7 8
-----------------------OPEN------------------------
TIMER
RADIO
OSC
LOCK
1-PASS
SLAVE
BRAKE
OPEN L/R
OFF ON
NOTE:
IF ANY CHANGES ARE
MADE TO THE DIP
SWITCHES WITH THE
POWER ON, PRESS THE
MAIN RESET
BUTTON TO
RECOGNIZE THE CHANGE
RESET
TURN SWITCH #6 “ON”
(SLAVE BOARD ONLY)
CONNECT SHIELD TO
SLAVE OPERATOR
FRAME ONLY
USE UL LISTED
CONDUIT
SHIELDED
CABLE
MASTER BOARD SLAVE BOARD