12
11
ELECTRICAL CONNECTION
Ÿ
All gate operators
MUST
be properly grounded. This minimizes or prevents damage due to electrical charge,
such as a near lightning strike or an electrical static discharge.
Ÿ
Use a single wire for the ground.
DO NOT
splice two wires for the ground. If the wire breaks or is cut, replace it
with a single length wire.
NEVER
use two wires for the ground.
Ÿ
Check the local city code for proper earth ground rod type and grounding procedures.
Ÿ
Use UL listed conduits for power wire enclosure.
OPERATORS
MUST
BE PROPERLY GROUNDED!
ELECTRICAL
CONNECTION BOX
X
X
POWER SWITCH
OFF
OFF
ON
ON
Ÿ
Use a minimum of a
20-AMP
, dedicated circuit for power.
OPERATOR WIRES
120 VAC FROM BREAKER
BLACK
120VAC (HOT)
WHITE
AC NEUTRAL
GREEN
GROUND
GATE TRAVEL ADJUSTMENT
X
X
OFF
ON
GEAR
BOX
EACH NOTCH
EQUALS
ABOUT 1/2” OF
TRAVEL
EACH NOTCH
EQUALS ABOUT
1/2” OF TRAVEL
LIMIT NUTS
LIMIT NUT LOCK PLATE
SL-100 AC[FP]
LIMIT NUTS
LIMIT SWITCH
LIMIT NUT LOCK PLATE
SL-150 AC
Locate the limit switches (limit switches will be in the limit box on SL-150 AC) and follow the steps below:
1: Turn the power
OFF
on the operator.
2: Push the limit lock plate down (on the SL-100 AC) or outwards (on the SL-150 AC).
3: Turn the limit nut toward the switch to DECREASE travel and away from the switch to INCREASE
travel.
4: Place limit plate back to its locked position. (
MUST
be done for gate to hold its limits)
5: Turn the power
ON
to the operator.
6: Run the gate operator open and close. If additional adjustment is needed, repeat the steps.