16
15
PROGRAMMABLE RELAY AND LEAF DELAY
Board model ALL-ACUL includes a programmable relay (N.O.) with four different configurations.
See table below for switch settings. Use the “Leaf Delay” potentiometer to adjust the delay time from
0 to 6 seconds.
(1) 1 second pulse for every open start cycle
- Typically used for a cycle counter
(2) “ON” when the gate is in motion
- Typically used for an audible alarm or strobe light to warn when the gate is in motion
(3) Alarm system output
- Activates the relay when the gate is forced open
(4) “ON” when gate is not fully closed
- Typically used for an indicator
S1
S2
RELAY FUNCTION
OFF
OFF
ONE SECOND PULSE FOR EVERY OPEN START CYCLE
ON
OFF
ON WHEN GATE IS IN MOTION
OFF
ON
ALARM SYSTEM OUTPUT
ON
ON
ON WHEN GATE IS NOT FULLY CLOSED
DEVICE
DEVICE
POWER SUPPLY
0 TO 6 SECOND
DELAY ADJUSTMENT
1 2
OPEN
3
1
3
DELAY
DIP SWITCH 3
OPENING AND CLOSING
DELAY FUNCTION SETTING
TIMER ADJUSTMENT AND RADIO SETTING
1 2 3 4 5 6 7 8
-----------------------OPEN------------------------
TIMER
RADIO
OSC
LOCK
1-PASS
SLAVE
BRAKE
OPEN L/R
OFF ON
1
3
RADIO “
” =
ON
ALLOWS THE
TRANSMITTER TO CLOSE
THE GATE BEFORE THE TIMER
TIMER “
” TO
ON
ACTIVATE THE TIMER
TIMER ON:
Automatic timer to close can be set from 1 to 60 seconds
TIMER OFF:
Gate operation is “push button to open, push button to close”
RADIO ON:
To override the timer and allow the radio receiver to close the gate before the timer
Turn potentiometer counter clockwise for more time
Turn potentiometer clockwise for less time
NOTE:
If potentiometer is turned all the way counter clockwise, the timer is disabled and the gate WILL NOT
close automatically
.
60
SEC
0
SEC
60
SEC
0
SEC