49
HD-TVI 23x Zoom PTZ Camera User Manual
PRELIMINARY
SECTION 4: CONFIGURING THE PTZ CAMERA
2.
Choose the alarm number.
a.
Move the cursor to
ALARM NUM
, then click the
IRIS+
to enter edit mode.
b.
Click the up and down direction buttons to select the number of the alarm which is to be configured.
c.
Click
IRIS+
again to confirm and exit edit mode of this column.
3.
Configure the alarm input.
a.
Move the cursor to
ALARM INPUT
, then click the
IRIS+
to enter edit mode.
b.
Click the up and down direction buttons to set the input status. You can configure it as
OPEN
(normally open),
CLOSE
(normally closed) or
OFF
(disable the alarm input).
—
OPEN
: If you set the status as
OPEN
, alarm will be triggered by a closed circuit between the alarm input and
alarm ground.
—
CLOSE
: If you set the status as
CLOSE
, alarm will be triggered by open circuit between the alarm input and
alarm ground.
—
OFF
: If you set the status as
OFF
, it will not be triggered.
c.
Click
IRIS+
again to confirm your selection.
4.
Configure the alarm linkage action.
You can specify the linked action when an alarm occurs. On the
ALARM AC
parameter, you can set the alarm action as preset
from 1 to 8, pattern from 1 to 4, patrol from 1 to 8, panning scan, tilting scan, random scan, frame scan, panoramic scan,
day mode, night mode or none. You can also set the alarm output for the alarm. See “4.12.2 AUXS submenu (Auxiliary alarm
output)” on page 51 for more information.
5.