9
HD-TVI 23x Zoom PTZ Camera User Manual
PRELIMINARY
SECTION 2: INSTALLATION
SECTION 2
Installation
Before you start, check the package contents and make sure that the device in the package is in good condition and all the assembly
parts are included. Included are:
•
AC power supply
•
Installation guide (this user manual)
Mounting brackets are sold separately.
2.1 Set the DIP switches
DIP switches, located in the housing are used to setup the RS-485 network address (switches 1 - 5), baud rate (switches 6 - 7), and
protocol (switches 8 - 9). These switches can also be setup manually or through the DVR PTZ interface.
The default DIP switch settings configure the camera for:
—
RS-485 address: 0
—
Baud Rate: 2400
—
RS-485 termination resistor: Off
Using the tables below, set the switches in accordance with the following:
•
The address of each device (camera) on the RS-485 network must be different.
•
The baud rate must be the same for each device on the RS-485 network.
•
The DIP switches 1 - 9, used for setting the address, baud rate, and protocol of the RS-485 network, function logically in this
way: ON=1 and OFF=0.
•
The camera is self-adaptive to the Pelco-P, Pelco-D and Private-Code protocols. You don’t have to set the DIP switches for these
RS-485 control protocol.
•
DIP switch 10 provides RS-485 end-of-line termination and cannot be set using the DVR interface. If used, it must be set by
opening the camera enclosure and manually setting the switch to ON.
•
To set the DIP switches manually, do the following:
1.
Remove the lower dome cover from the camera by extracting the three screws.