26
TREE #2
INLET VALVE CLOSES DURING OPERATION
Is current
per table
values?
Is
vaporizer
warm as
outlet
pressure
drops?
Clean inlet
screen
debris
Measure current
as pressure drops
YES
YES
YES
NO
NO
NO
1. Exceeding vaporizer
capacity. Lower capacity
or add additional
vaporizers.
2. Thermal valve probe
not pushed all the way in
the thermowell. Check
for probe insertion depth.
Allow ZIMMER to
completely cool for 5-6
hours. Apply power
and measure current
after 20 seconds.
Is there frosting
or water
condensation
on any of the
inlet piping?
Correct
pressure
losses in liquid
piping
Current per El.
Specification
table in
Appendix?
Heater
system not
functioning.
Contact ASDI
NO
YES
Debris
on inlet
screen?
Check fuel
composition
meets valve
limits
YES
NO