alfen Eve Single Pro Series Manual Download Page 24

24

Eve Single manual  |  Version 4.2 |  December 2021

ENGLISH

5. CONNECTIVITY

5.4 Register your charging station to your own 

backoffice management system

When using a non-Alfen management system, it is essen-
tial that you register the charging station model. The Eve 
Single model will send a ChargePointModel in accordance 
with OCPP specifications when logging in. 

 

The table below indicates available options.

 

Article no.

Description

 

ChargePointModel

904460003

Eve Single Pro-
line 1PH T2

NG910-60003

904460005

Eve Single Pro-
line 1PH T2S

NG910-60005

904460007

Eve Single Pro-
line 1PH Cable

NG910-60007

904460023

Eve Single Pro-
line 3PH T2

NG910-60023

904460025

Eve Single Pro-
line 3PH T2S

NG910-60025

904460027

Eve Single Pro-
line 3PH Cable

NG910-60027

904460123

Eve Single Pro-
line DE 3PH T2

NG910-60123

904460127

Eve Single 
Pro-line DE 3PH 
Cable

NG910-60127

904460503

Eve Single S-line 
1PH T2

NG910-60503

904460505

Eve Single S-line 
1PH T2S

NG910-60505

904460507

Eve Single S-line 
1PH Cable

NG910-60507

904460523

Eve Single S-line 
3PH T2

NG910-60523

904460525

Eve Single S-line 
3PH T2S

NG910-60525

904460527

Eve Single S-line 
3PH Cable

NG910-60527

904460553

Eve Single S-line 
1PH T2 RFID

NG910-60553

904460555

Eve Single S-line 
1PH T2S RFID

NG910-60555

904460557

Eve Single S-line 
1PH Cable RFID

NG910-60557

904460573

Eve Single S-line 
1PH T2 Mobile

NG910-60573

904460575

Eve Single S-line 
1PH T2S Mobile

NG910-60575 

904460577

Eve Single S-line 
1PH Cable Mobile

NG910-60577

904460583

Eve Single S-line 
3PH T2 RFID

NG910-60583

904460585

Eve Single S-line 
3PH T2S RFID

NG910-60585 

904460587

Eve Single S-line 
3PH Cable RFID

NG910-60587

904460593

Eve Single S-line 
3PH T2 Mobile

NG910-60593

904460595

Eve Single S-line 
3PH T2S Mobile

NG910-60595 

904460597

Eve Single S-line 
3PH Cable Mobile

NG910-60597

Summary of Contents for Eve Single Pro Series

Page 1: ...Eve Single Manual Handleiding Handbuch Manuel K ytt opas S line Pro line...

Page 2: ......

Page 3: ...socket model met stopcontact Modell mit Steckdose mod le avec prise pistorasialla varustettu malli INSIDE BINNENZIJDE INNENSEITE INT RIEUR SIS PUOLI OUTSIDE BUITENZIJDE AUSSEN EXT RIEUR ULKOPUOLELLA...

Page 4: ...t model met stopcontact Modell mit Steckdose mod le avec prise pistorasialla varustettu malli Exterior view Buitenzijde Aussenansicht Ext rieur Ulkopuolella 1 1 3a 3b 2 2 11 10a 8 9 10b 11 11 10a 11 7...

Page 5: ...ilisation of all advanced features of your charging station we recommend that you read this manual carefully and save it for future reference While we have done our utmost to provide you with a comple...

Page 6: ...s 14 2 6 Accessories 15 2 7 Technical specifications for installation 16 2 7 1 External protection according to EV ZE Ready standard 16 3 Assembly and connecting 16 3 1 Safety Instructions 17 3 2 Asse...

Page 7: ...individual components are damaged Usage by children or individuals not able to properly assess the risks associated with using this product Alfen ICU B V shall not be liable in any way for any kind o...

Page 8: ...or plug holder 4 RGB Status LED Interior view Interior view 5 UTP Ethernet connector 5 UTP Ethernet connector 6 RJ11 connector 6 RJ11 connector 7 7 SIM cardholder 8 Terminal block for the power supply...

Page 9: ...Charge card accepted cable connected Communicating with vehicle or charging complete Charging transaction active Status indicators during smart EV charging load balancing The Eve Single S line will i...

Page 10: ...3 2 3 Operation Specific user actions are presented in a sequence that cearly shows the progress and corresponding status indications The first steps can be conducted in any sequence Upon detecting a...

Page 11: ...h h kW kW kWh h Models with fixed charging cable Models with socket Models with socket Models with fixed charging cable Pro line Pro line Pro line Pro line 2 4 1 3 2 4 1 3 2 4 1 3 2 4 1 3 RFID Chargin...

Page 12: ...to undo the action To close the database hold the Master Key in front of the card reader once more Hold the Master Key in front of the card reader Hold the charge pass that you want to add in front o...

Page 13: ...C detector that protects the earth leakage circuit breaker against DC leak age currents The DC detector prevents type A earth leakage circuit breakers from becoming blind to dangerous leakage currents...

Page 14: ...ts default casing colour RAL9016 Other darker colours may have an adverse effect on the product If the product is exposed to lower or higher temperatures continuous operation cannot be guaranteed If t...

Page 15: ...x Quick Installation Guide 1 x M8 nut 4 x M25 x 1 5 For model with fixed charging cable 2 x 2 PRODUCT 2 6 Accessories Item Details Article no Mounting post 803873036 ICU Pole dimensions H x W x D Bas...

Page 16: ...ase 16A 11kW 3 x 20A gG 1 phase 32A 7 4kW 1 x 35A gG 3 phase 32A 22kW 3 x 35A gG Residual current protection possibly i c w circuit breakers Earth leakage circuit breakers 30mA type A or B 4P 3 7kW 11...

Page 17: ...short circuiting and overcurrent with a B or C type circuit breaker or other in accordance with local standards and regulations or gG type fuses or other in accordance with local standards and regula...

Page 18: ...ring and the construction Spirit level Drill machine Torque driver for terminal block connections 3 5 Installation procedure prerequisites The installation location is a solid wall In the surroundings...

Page 19: ...ount the charging station on the wall mount frame Connect the earth wire on the bottom right threaded end of the wall mount frame Use the M8 washer and nut for installation 3 7 Electrical installation...

Page 20: ...tion Screw the front cover back onto the charging station with the Torx T20 wrench Use all six screws for this Models with display Connect the display connector 3 10 Data cable options 3 10 1 Connecti...

Page 21: ...ionality If so check the settings with the Service Installer application to optimally configure the charging station for the local situation More information is available in Appendix B 4 3 Commissioni...

Page 22: ...the smart charge options see Appendix B check the settings and adjust them where necessary to optimally configure the charging station for its location The Service Installer application is divided in...

Page 23: ...isconnect the transpa rent subframe 3 x Torx T20 screw To install a card access the SIM cardholder from the left side This will provide you with more space Be careful not to crush any cables while rep...

Page 24: ...4460127 Eve Single Pro line DE 3PH Cable NG910 60127 904460503 Eve Single S line 1PH T2 NG910 60503 904460505 Eve Single S line 1PH T2S NG910 60505 904460507 Eve Single S line 1PH Cable NG910 60507 90...

Page 25: ...charge point supplier Check powerboard 105 Not able to charge Please call for support Internal error No communication with internal power meter Contact the service department of your charge point supp...

Page 26: ...Cable connected for more than 2 minutes without starting a charging session Reconnect cable and start charging session within 2 minutes Otherwise contact the service depart ment of your charge point...

Page 27: ...ging cable is out of range according to the IEC 61851 norm One specific cable Issues with other charge points Cable broken All cables No issue with oth er charge point Contact the service department o...

Page 28: ...20 metres combined with the P1 port Always check if the communi cation with the smart meter is working properly The quality of the signals depend on several factors Therefore always limit the cable le...

Page 29: ...e network operator Subnet mask of the local network Modbus address of the energy meter Default gateway of the local network Factory settings Options Values SCN NetworkName Name of the SCN Maximum of 8...

Page 30: ...0 1 W SIGNED32 Reactive Power L1 VAr 0 1 VAr SIGNED32 Reactive Power L2 VAr 0 1 VAr SIGNED32 Reactive Power L3 VAr 0 1 VAr SIGNED32 Apparent Power L1 VA 0 1 VA UNSIGNED32 Apparent Power L2 VA 0 1 VA...

Page 31: ...0Mbps network UDP port 36549 inbound outbound Use the DHCP server if possible Without a DHCP server the charging stations obtain an IP address via Auto IP All charging stations are fed from the same p...

Page 32: ...e SCN if you have not purchased this functionality After you receive confirmation for your purchase of this functionality by Alfen the new functionality can be downloaded using the Service Installer a...

Page 33: ...ely For this purpose all local authorities have established collection schemes under which residents can dispose waste electrical and electronic equipment at a recycling centre or other collection poi...

Page 34: ......

Page 35: ...1 0 36 54 93 401 Website www alfen com nl oplaadpunten ev www alfen com en ev charge points Contact Contact Kontakt Contact Yhteystiedot Alfen ICU B V Hefbrugweg 28 1332 AP Almere The Netherlands P O...

Reviews: