background image

Installation Manual 5850-023

TE91K022-EN3

 

BADK 082012 

INITIALLY ISSUED: 3/30/2010 

AUTHORIZATION NUMBER: 1536 

THIS IS TO CERTIFY THAT 

Alfa Laval Inc.

Baldershoj 19, DK 2635 Ishoj, DENMARK  

is hereby authorized to continue to apply the

3-A Symbol to the models of equipment, conforming to 3-A Sanitary Standards for: 

Number: 74-03, Sensors and Sensor Fittings and Connections

set forth below

Conductivity Sensor: TE67K1711111x3 or 4; Level Switch: TE67O0211110x3, 4, 9, 

A, C, D, F, or G; Potentiometric Level Transmitter: TE67H021xxx3x3 or 4; 

Temperature Transmitter: TE67Gx11xxxxx3, 4, 5, or 7.

VALID THROUGH: 

December 31, 2012

Timothy R. Rugh 
Executive Director, 3-A Sanitary Standards, Inc.

The issuance of this authorization for the use of the 3-A Symbol is based upon the voluntary 
certification, by the applicant for it, that the equipment listed above complies fully with the 3-A 
Sanitary Standards designated. Legal responsibility for compliance is solely that of the holder of 
this Certificate of Authorization, and 3-A Sanitary Standards, Inc. does not warrant that the 
holder of an authorization at all times complies with the provisions of the said 3-A Sanitary 
Standards. This in no way affects the responsibility of 3-A Sanitary Standards, Inc. to take 
appropriate action in such cases in which evidence of nonconformance had been established.

NEXT TPV INSPECTION/REPORT DUE: 

March 2015

Summary of Contents for TE67K Series

Page 1: ...Alfa Laval Conductivity Transmitter TE67Kxxxxxxxxx have according to the type been developed for applications where conduc tivity and temperature are to be measured Inductive conductivity measurement is based on the principle of two series connected toroidal core transformers 1 and 2 The primary side of the transformer 1 is controlled by an AC voltage generator The liquid flowing through the chann...

Page 2: ... Insert length L 40 Standard sensor shaft Insert length L 87 Extended sensor shaft Mechanical Installation Dimensional Drawing After Installation and Configuration Check the leak tightness of the sleeve Check the tightness of glands or M12 plugs Check the tightness of the cover ø89 Clamp 1 1 2 ISO2852 DIN32676 TEK67K1311111xx TE67K1211111xx Clamp 2 ISO2852 DIN32676 TEK67K1711111xx TE67K1811111xx G...

Page 3: ...our measuring ranges All four measuring ranges can individually be set to a range according to the table The 3 A mark is valid only when the product is mounted in a 3 A marked counter part and installed according to the installation manual Use also a 3 A marked O ring or gasket if relevant The 3 A marked products conforms to the 3 A Sanitary Standard criteria Materials and surfaces fulfill the FDA...

Page 4: ...y Sensor Configuring the Alfa Laval Conductivity Sensor Jog shuttle Step Subject Range Display Turn Push Note 1 Power on starting 2 Actual value 1 yyyyy mS zzzzz C Push 3 SW version Actual version Push 4 Actual value 1 yyyyy mS zzzzz C Right 5 Set Range 1 1 4 20 mA Actual range mS Push Note 1 6 1 4 20 mA Set range mS Left Right Push to set Left Decrease Right Increase 7 1 4 20 mA New range mS Righ...

Page 5: ...ns contained in this manual were effective at the date of printing However as continuous improvements are our policy we reserve the right to alter or modify any unit specification on any product without prior notice or any obligation Reservation and contact infomation 2012 Alfa Laval Corporate AB This document and its contents is owned by Alfa Laval Corporate AB and protected by laws governing int...

Page 6: ...lenght 37 mm TE67Kx7xxxxxxx Clamp DN 50 ISO2852 Clamp DN 51 DIN32676 with sensor shaft lenght 84 mm TE67Kx8xxxxxxx DN 32 Din11851 L 37mm TE67KxAxxxxxxx DN 40 Din11851 L 37mm TE67KxBxxxxxxx DN 50 Din11851 L 37mm TE67KxCxxxxxxx DN 32 Din11851 L 84mm TE67KxDxxxxxxx DN 40 Din11851 L 84mm TE67KxExxxxxxx DN 50 Din11851 L 84mm TE67KxFxxxxxxx Surface finish wetted parts Ra 0 8µ TE67Kxx1xxxxxx Ra 0 4µ Elec...

Page 7: ...UGH December 31 2012 Timothy R Rugh Executive Director 3 A Sanitary Standards Inc The issuance of this authorization for the use of the 3 A Symbol is based upon the voluntary certification by the applicant for it that the equipment listed above complies fully with the 3 A Sanitary Standards designated Legal responsibility for compliance is solely that of the holder of this Certificate of Authoriza...

Page 8: ...Installation Manual 5850 023 TE91K022 EN3 BADK 082012 ...