Ordering key table

Alfa Laval Conductivity Sensor 

 

Ver 2 _ 07_09_2010

Desription 

Option 

Item nr. code

Measuring range

 

0,01 to 999 mS/cm 

TE67K1xxxxxxxx

 

Clamp DN 38 (ISO2852) / Clamp DN 40  

 (DIN32676)

Process connection

 

with sensor shaft lenght 37 mm 

TE67Kx2xxxxxxx

 

Clamp DN 38 (ISO2852) / Clamp DN 40  

 (DIN32676) 
 

with sensor shaft lenght 84 mm 

TE67Kx3xxxxxxx

 

G1“ (ISO228) L:84 mm 

TE67Kx5xxxxxxx

 

G1“ (ISO228) L:37 mm 

TE67Kx6xxxxxxx

 

Clamp DN 50 (ISO2852) /  

 

Clamp DN 51 (DIN32676) with sensor  

 

shaft lenght 37 mm 

TE67Kx7xxxxxxx

 

Clamp DN 50 (ISO2852) /  

 

Clamp DN 51 (DIN32676) with sensor  

 

shaft lenght 84 mm 

TE67Kx8xxxxxxx

 

DN 32 (Din11851)  L=37mm 

TE67KxAxxxxxxx

 

DN 40 (Din11851)  L=37mm 

TE67KxBxxxxxxx

 

DN 50 (Din11851)  L=37mm 

TE67KxCxxxxxxx

 

DN 32 (Din11851)  L=84mm 

TE67KxDxxxxxxx

 

DN 40 (Din11851)  L=84mm 

TE67KxExxxxxxx

 

DN 50 (Din11851)  L=84mm 

TE67KxFxxxxxxx

Surface finish wetted parts

 Ra<0,8µ 

TE67Kxx1xxxxxx

 

Ra<0,4µ (Electropolished) 

TE67Kxx2xxxxxx

Wetted part materiale

 

AISI316L and PEEK 

TE67Kxxx1xxxxx

Powersupply

 

14-36 Vdc 

TE67Kxxxx1xxxx

Electrical output

 4-20mA 

TE67Kxxxxx1xxx

Accuracy

 

± 1% FS 

TE67Kxxxxxx1xx

Others

 

electrical connection:M12 plug 

TE67Kxxxxxxx3x

 

Cable gland M16 

TE67Kxxxxxxx4x

Certificates

 

3.1 Certificate 

TE67Kxxxxxxxx2

 

3.1. Certi 3A 

TE67Kxxxxxxxx3

 3A 

TE67Kxxxxxxxx4

 N/A 

TE67Kxxxxxxxx0

Summary of Contents for TE67K Series

Page 1: ...Alfa Laval Conductivity Transmitter TE67Kxxxxxxxxx have according to the type been developed for applications where conduc tivity and temperature are to be measured Inductive conductivity measurement is based on the principle of two series connected toroidal core transformers 1 and 2 The primary side of the transformer 1 is controlled by an AC voltage generator The liquid flowing through the chann...

Page 2: ... Insert length L 40 Standard sensor shaft Insert length L 87 Extended sensor shaft Mechanical Installation Dimensional Drawing After Installation and Configuration Check the leak tightness of the sleeve Check the tightness of glands or M12 plugs Check the tightness of the cover ø89 Clamp 1 1 2 ISO2852 DIN32676 TEK67K1311111xx TE67K1211111xx Clamp 2 ISO2852 DIN32676 TEK67K1711111xx TE67K1811111xx G...

Page 3: ...our measuring ranges All four measuring ranges can individually be set to a range according to the table The 3 A mark is valid only when the product is mounted in a 3 A marked counter part and installed according to the installation manual Use also a 3 A marked O ring or gasket if relevant The 3 A marked products conforms to the 3 A Sanitary Standard criteria Materials and surfaces fulfill the FDA...

Page 4: ...y Sensor Configuring the Alfa Laval Conductivity Sensor Jog shuttle Step Subject Range Display Turn Push Note 1 Power on starting 2 Actual value 1 yyyyy mS zzzzz C Push 3 SW version Actual version Push 4 Actual value 1 yyyyy mS zzzzz C Right 5 Set Range 1 1 4 20 mA Actual range mS Push Note 1 6 1 4 20 mA Set range mS Left Right Push to set Left Decrease Right Increase 7 1 4 20 mA New range mS Righ...

Page 5: ...ns contained in this manual were effective at the date of printing However as continuous improvements are our policy we reserve the right to alter or modify any unit specification on any product without prior notice or any obligation Reservation and contact infomation 2012 Alfa Laval Corporate AB This document and its contents is owned by Alfa Laval Corporate AB and protected by laws governing int...

Page 6: ...lenght 37 mm TE67Kx7xxxxxxx Clamp DN 50 ISO2852 Clamp DN 51 DIN32676 with sensor shaft lenght 84 mm TE67Kx8xxxxxxx DN 32 Din11851 L 37mm TE67KxAxxxxxxx DN 40 Din11851 L 37mm TE67KxBxxxxxxx DN 50 Din11851 L 37mm TE67KxCxxxxxxx DN 32 Din11851 L 84mm TE67KxDxxxxxxx DN 40 Din11851 L 84mm TE67KxExxxxxxx DN 50 Din11851 L 84mm TE67KxFxxxxxxx Surface finish wetted parts Ra 0 8µ TE67Kxx1xxxxxx Ra 0 4µ Elec...

Page 7: ...UGH December 31 2012 Timothy R Rugh Executive Director 3 A Sanitary Standards Inc The issuance of this authorization for the use of the 3 A Symbol is based upon the voluntary certification by the applicant for it that the equipment listed above complies fully with the 3 A Sanitary Standards designated Legal responsibility for compliance is solely that of the holder of this Certificate of Authoriza...

Page 8: ...Installation Manual 5850 023 TE91K022 EN3 BADK 082012 ...

Reviews: