Installation Manual 5850-023

TE91K022-EN3

 

BADK 082012 

Alfa Laval Conductivity Sensor

Safety instructions

This instrument is built and tested according to the current EU-direc-
tives and packed in technically safe condition. In order to maintain this 
condition and to ensure safe operation, the user must follow the hints 
and warnings given in this instruction.

During the installation the valid national rules have to be observed. 
Ignoring the warnings may lead to severe personal injury or substantial 
damage to property.

The product must be operated by trained staff. Correct and safe 
operation of this equipment is dependent on proper transport, storage, 
installation and operation.

All electrical wiring must conform to local standards. In order to 
prevent stray electrical radiation, we recommend twisted and shielded 
input cables, as also to keep power supply cables separated from the 
input cables. The connection must be made according to the connect-
ing diagrams.

Before switching off the supply voltage check the possible effects on 
other equipment and the processing system. Ensure that the supply 

voltage and the conditions in the environment comply with the specifi

-

cation of the device. 

This instruction manual is part of the device, must be kept nearest its 
location, always accessible to all employees. This instruction manual is 

copyrighted. The contents of this instruction manual reflect the version 

available at the time of printing. It has been issued to our best knowl-
edge. However, errors may have occurred. Alfa Laval Tank Equipment 
A/S is not liable for any incorrect statements and their effects.    

– Technical modifications reserved –   

Limitation of liability

By non-observance of the instruction manual, inappropriate use, 

modification or damage, no liability is assumed and warranty claims 

will be excluded.   

Intended use

The Alfa Laval Conductivity Transmitter  TE67Kxxxxxxxxx have, 
according to the type, been developed for applications where conduc-
tivity and temperature are to be measured.  

Inductive conductivity measurement is based on the principle of two 
series-connected toroidal-core transformers (1) and (2).
The primary side of the transformer 1 is controlled by an AC voltage 
generator.

The liquid flowing through the channel bore (3) in the measuring head 

form a conductor loop, which links between the secondary side of 
the transformer (1) and the primary side of the transformer (2). The 
output current is proportional with the conductivity of the media. Signal 

conditioning, amplification and conversion provides a 4...20 mA signal 

output from the galvanically isolated D/A converter.
The measured conductivity is highly dependable of the media tem-

perature. Therefore the fast-response temperature sensor in the tip (4) 

compensates for the temperature in the media.
The special processing unit offers maximum accuracy and reliability.
The very low resolution of 1µS/cm together with a fast response time 
gives a high sensivity. This ensures reliable detection of media even 
with minor differences in conductivity, such as different kinds of beer.

Functional Principle

2

1

3

2

1

4

A

D

D

A

Proc.

AC

4...20 mA

 

outputs

TE67Kxxxxxxxxx

R

74 - 03

It is the operator’s   responsibility to check and verify the suitability of 
the device  for the intended application. If any doubts remain, please 
contact our local Alfa Laval Company in order to ensure proper usage. 
Alfa Laval Tank Equipment A/S is not liable for any incorrect selections 
and their effects.    

– The technical data listed in the current data sheet are engaging and 
must be complied with. If the data sheet is not available, please order 
or download it from our homepage (http://www.alfalaval.com)    

* WARNING!

 

Danger through improper usage.

Package contents

Please verify that all listed parts are undamaged included in the deliv-

ery and check for consistency specified in o

ur order:    

– Conductivity transmitter    
– Mounting instructions   

Summary of Contents for TE67K Series

Page 1: ...Alfa Laval Conductivity Transmitter TE67Kxxxxxxxxx have according to the type been developed for applications where conduc tivity and temperature are to be measured Inductive conductivity measurement is based on the principle of two series connected toroidal core transformers 1 and 2 The primary side of the transformer 1 is controlled by an AC voltage generator The liquid flowing through the chann...

Page 2: ... Insert length L 40 Standard sensor shaft Insert length L 87 Extended sensor shaft Mechanical Installation Dimensional Drawing After Installation and Configuration Check the leak tightness of the sleeve Check the tightness of glands or M12 plugs Check the tightness of the cover ø89 Clamp 1 1 2 ISO2852 DIN32676 TEK67K1311111xx TE67K1211111xx Clamp 2 ISO2852 DIN32676 TEK67K1711111xx TE67K1811111xx G...

Page 3: ...our measuring ranges All four measuring ranges can individually be set to a range according to the table The 3 A mark is valid only when the product is mounted in a 3 A marked counter part and installed according to the installation manual Use also a 3 A marked O ring or gasket if relevant The 3 A marked products conforms to the 3 A Sanitary Standard criteria Materials and surfaces fulfill the FDA...

Page 4: ...y Sensor Configuring the Alfa Laval Conductivity Sensor Jog shuttle Step Subject Range Display Turn Push Note 1 Power on starting 2 Actual value 1 yyyyy mS zzzzz C Push 3 SW version Actual version Push 4 Actual value 1 yyyyy mS zzzzz C Right 5 Set Range 1 1 4 20 mA Actual range mS Push Note 1 6 1 4 20 mA Set range mS Left Right Push to set Left Decrease Right Increase 7 1 4 20 mA New range mS Righ...

Page 5: ...ns contained in this manual were effective at the date of printing However as continuous improvements are our policy we reserve the right to alter or modify any unit specification on any product without prior notice or any obligation Reservation and contact infomation 2012 Alfa Laval Corporate AB This document and its contents is owned by Alfa Laval Corporate AB and protected by laws governing int...

Page 6: ...lenght 37 mm TE67Kx7xxxxxxx Clamp DN 50 ISO2852 Clamp DN 51 DIN32676 with sensor shaft lenght 84 mm TE67Kx8xxxxxxx DN 32 Din11851 L 37mm TE67KxAxxxxxxx DN 40 Din11851 L 37mm TE67KxBxxxxxxx DN 50 Din11851 L 37mm TE67KxCxxxxxxx DN 32 Din11851 L 84mm TE67KxDxxxxxxx DN 40 Din11851 L 84mm TE67KxExxxxxxx DN 50 Din11851 L 84mm TE67KxFxxxxxxx Surface finish wetted parts Ra 0 8µ TE67Kxx1xxxxxx Ra 0 4µ Elec...

Page 7: ...UGH December 31 2012 Timothy R Rugh Executive Director 3 A Sanitary Standards Inc The issuance of this authorization for the use of the 3 A Symbol is based upon the voluntary certification by the applicant for it that the equipment listed above complies fully with the 3 A Sanitary Standards designated Legal responsibility for compliance is solely that of the holder of this Certificate of Authoriza...

Page 8: ...Installation Manual 5850 023 TE91K022 EN3 BADK 082012 ...

Reviews: