5 Maintenance
5.2 Maintenance schedule
It is advisable to install pressure gauges on both sides of the pump so that any problems within the pump/pipework can
be monitored.
M
Maaiinntteennaannccee sscchheedduullee
Y
Yoouurr w
weeeekkllyy sscchheedduullee sshhoouulldd iinncclluuddee::
- Checking the seals for leakage.
- Checking the lip seals for leakage.
- Check pumping pressures are within expected duty.
- Check oil level in the gearcase with pump stationary.
- Check that any guarding is securely affixed in position and is in good condition.
Checks should be carried out when the pump is not operational, and any electrical supply has been safely disconnected
and locked so accidental operation cannot occur. In certain operational circumstances the pump will pose a thermal
hazard and as such should not be touched during operation. After shutdown the pump unit should be allowed time to
cool to ambient temperature.
R
Reeccoom
mm
meennddeedd S
Sppaarree P
Paarrttss
P
Paarrtt ddeessccrriippttiioonn
Q
Quuaannttiittyy
Service kit for the mechanical seal
1
Profiled elastomer kit for wet end
1
The table shows recommended spare parts that should be retained
within your maintenance schedule.
21