4 Installation
S
Stteepp 33
After receipt and inspection, if the pump is not to be installed immediately, the pump should be repacked in the original
packaging and placed in suitable storage. The following points should be noted:
- Plastic or gasket type port covers should be left in place.
- Pumps received wrapped with corrosion inhibiting treatment material should have wrapping replaced.
- A clean, dry storage location free from vibration should be selected. If a moist or dusty atmosphere is used for storage,
further protect the pump or unit with a suitable cover.
- A clean, dry storage location free from vibration and without direct sunlight or UV light should be selected.
- Temperature range between -5 to +40
o
C (23 to 104
o
F)
- Relative humidity <60%.
- If a moist or dusty atmosphere is used for storage, further protect the pump or unit with a suitable cover.
- No exposure to corrosive substances, including those contain in the air.
- Rotate the pump/pump unit by hand weekly, to prevent bearing damage.
- All associated ancillary equipment should be treated similarly.