3. TECHNICAL DATA
Method
MIG/
MAG
MMA
TIG
MIG/
MAG
MMA
TIG
Mains voltage
V/Hz
1x110/50-60
1x230/50-60
Welding current range
A
20 - 130 10 - 100 10 - 140 20 - 200 10 - 200 10 - 200
Open-circuit voltage U
20
V
67,0
67,0
Mains protection
A
25 @
16 @
Max. effective current
I
1eff
A
22,0
17,5
18,0
14,9
15,7
12,0
Welding current
(DC=100%) I
2
A
85
65
95
130
120
140
Welding current
(DC=60%) I
2
A
110
80
125
150
140
150
Welding current
(DC=x%) I
2
A
35%=
130
30%=
100
40%=
140
30%=
200
25%=
200
35%=
200
Protection
IP 23S
Standards
EN 60974-1; EN 60974-10 cl. A
Dimensions (w x l x h)
mm
215 x 540 x 410
Weight
kg
17,7
Wire speed
m/mi
n
1,5 - 4,5
---
---
1,5 -
17,0
---
---
Spool diameter
mm
200
---
---
200
---
---
Spool weight
kg
5
---
---
5
---
---
ALFA IN continuously strives to produce the best product possible and therefore
reserves the right to change, improve or revise the specifications or design of
this or any product without prior notice. Such updates or changes do not entitle
the buyer of equipment previously sold or shipped to the corresponding changes,