8. GETTING STARTED TIG
Getting started must be consistent with technical data and conditions of use.
Fig. 15
Connecting the ground cable and the torch (illustrative picture)
1. Connect the torch
B12
to the quick connector (-)
B13
of welding cables to
the gas connector
B14
and connector
B10
.
2. Connect the ground cable to the
quick connector (+)
B9
of welding cables
and
the ground clamps
B11
to the weldment
B7
or to the welding table
.
3. Connect the machine to power supply and turn the main switch on the back
panel to ON.
4.
Connect
the
gas hose and
gas flow adjustment
described
in
ADJUSTMENT OF GAS FLOW.
5. In submenu of method selection select
TIG Lift
, see part 6. MAIN MENU.
6.
Use the knob
A4
to adjust
the welding current.
7.
Use the potentiometer
30
to adjust
the time of Slope down.
8. In submenu of welding parameters settings you can change values of Pre
Gas time and Post Gas time.