background image

AR2000 SLIDING GATE OPERATOR   

Conduit 

In order to protect the wires, conduit must be preset into the concrete when it is poured. Wires 

within the conduit shall be located or protected so that no damage can result from contact with 

any rough or sharp part. If you have installed an external button switch, we advise you to use 

two conduits: one for main power wire, another one for control wire. Always separate power 

wires from control wires. 

Concrete pad 

The base unit of the gate operator requires a concrete pad in order to maintain proper stability.   

The concrete pad should be approximately 400mm x 250mm x 200mm deep in order to provide 

for adequate operation.   

Anchors 

You can use the anchor bolts, anchors, washers, and nuts. These anchors must be set into the 

concrete when it is poured, or you can use wedge anchors. 

 

                                                                      Fig.5 

Operator Base 

Mount the gate operator base to the concrete pad.   

Operator 

Mount the gate operator to the base using nuts and washers. Verify that the operator is leveled 

properly. 

Installing the rack (see Fig.6) 

Weld the steel rack 

z

 

Manually move the gate to its closing position. 

z

 

Place the three threaded pawls (in the same package with rack) on the rack element. 

z

 

Lay the first piece of rack on the gear and weld the first threaded pawl on the gate.   

z

 

Move the gate manually, checking if the rack is resting on the gear, and weld the second 

and third pawls. 

z

 

Bring another rack element near to the previous one. Move the gate manually and weld the 

three pawls as the first rack, thus proceeding until the gate is fully covered. 

z

 

When the rack has been installed, to ensure it meshes correctly with the gear. 

z

 

The space between rack and gear is about 1mm. 

Screw the nylon rack 

z

 

Manually move the gate to its closing position. 

z

 

Lay the first piece of rack on the gear and mark the drilling point on the gate, drill a hole and 

screw the bolt. 

z

 

Move the gate manually, checking if the rack is resting on the gear, and repeat the above 

operations. 

z

 

Bring another rack element near to the previous one. Move the gate manually and carry out 

the securing operations, thus proceeding until the gate is fully covered. 

Summary of Contents for AR2000

Page 1: ...Sliding Gate Operator User s Manual Model AR2000...

Page 2: ...R 2 OUTLINE 1 Important safety information 3 2 Main features 3 3 Technical parameters 3 4 Working principle and main structure 4 5 Installation and adjustment 5 6 Electrical 8 7 Control 10 8 Maintenan...

Page 3: ...could be pinched z Do not allow control devices to be placed so that a person can access them by reaching through the gate z In the event of power failure an emergency release key allows you to opera...

Page 4: ...the worm with the clutch engaged the worm rotates the worm gear and output gear which pushes rack attached to the sliding gate thus moving the gate The dimension is shown in Fig 1 Fig 1 The structure...

Page 5: ...ncluding the stator the rotator of the motor the worm gear and the worm Output gear Pressure nut Mandrel Key Gear clutch Worm gear Fig 3 The device is equipped with a thermal protector the thermal pro...

Page 6: ...that the operator is leveled properly Installing the rack see Fig 6 Weld the steel rack z Manually move the gate to its closing position z Place the three threaded pawls in the same package with rack...

Page 7: ...on Fit the magnet bracket to the rack and then tighten the gear clutch The lower bracket is for open position and higher bracket is for close position Fix the magnet to the bracket Finally adjust the...

Page 8: ...ack Lower bracket Fig 8 6 Electrical Make sure that the power is OFF before making any electrical connections Remove the cover of the control box perform the wiring and replace the cover again Refer t...

Page 9: ...C66 13 Limit switch CL Close limit CO Com OP Open limit DC12V Output power supply CL COM OP N C For N C limit switch CL COM OP N O For N O limit switch Limit switch mode is adjustable by DIP switch Se...

Page 10: ...nal X8 No 15 Terminal X8 No 15 Terminal X8 No 15 Terminal X8 No 15 Loop detector with AC input Infrared with AC input Schematic diagram 16 Beeper DC12V 17 Learn button AN 18 Dip switch 19 Antenna ANT...

Page 11: ...will open the motor rotates clockwise the output voltage between D and D is AC110V the voltage between U and V is AC110V Press STOP button or the same remote control button the gate stops running Pres...

Page 12: ...se turn on the first and the second DIP switch See Fig 9 terminal 18 to ON position Press button 4 to open the gate see Verify open direction section Wait until the gate travels the distance according...

Page 13: ...mode has been re programmed in the device and replaced the original auto close time of pedestrian mode that you have been set in Set auto close function of pedestrian mode section Keep width of pedest...

Page 14: ...for people pass through z Safe guard Infrared photocell If infrared beam is interrupted during closing the gate will reverse and go open immediately This feature will not function if the gate is in fu...

Page 15: ...0 C you can select 45 oil Table 3 Parameters of DB25 transformer oil Kinematic viscosity 20 C Break down voltage Solidification point 30 Centistoke 35 kV 25 C Ensure the operator is well earthed and c...

Page 16: ...inal block becomes loose Check the limit switch mode see table 2 DIP switch Connecting wires or terminal blocks are too loose Check the connecting wires and terminal blocks The electric component on t...

Reviews: