AR2000 SLIDING GATE OPERATOR
12
z
Set auto-close function (This feature can be selected to make the gate stay open for some
seconds before it automatically closes. The auto-close time can be adjusted to between 0
and 44 seconds.): please turn on the first and the second DIP-switch (See Fig.9 terminal 18)
to ON position. Press the remote control button (button 1, button 2 or button 3) that has
been programmed to open the gate (see
Verify open direction
section). Stop the gate at
any position by pressing the same button, wait for some seconds according to your
requirements (the range is 1~44 sec.), this period of time is regarded as ‘auto-close time’.
Close the gate by pressing the same button. Press the button again to stop the gate or the
gate will stop at its closed position automatically if the limit switch is reached. After this
setup is complete, return DIP-switch 1 to OFF position immediately. Thus the auto-close
function has been set.
z
Cancel auto-close function:
please turn on the first and the second DIP-switch (see Fig.9
terminal 18) to ON position. Press the remote control button (button 1, button 2 or button 3)
that has been programmed to open the gate (see
Verify open direction
section). Stop the
gate at any position by pressing the same button, wait until the gate close automatically (45
sec.). Press the same button to stop the gate or the gate will stop at its closed position
automatically if the limit switch is reached. After this setup is complete, return DIP-switch 1
to OFF position immediately. Thus the auto-close function has been cancelled.
z
Pedestrian
mode:
Pedestrian mode can be used to open gate about 0.3~1.5 meters for
people pass through.
﹡
Set width of pedestrian mode: Please turn on the first and the second DIP-switch (See
Fig.9 terminal 18) to ON position. Press button 4 to open the gate (see
Verify open
direction
section), Wait until the gate travels the distance according to your requirements
(the distance range is 0.3m~1.5m or wait for 3~10 sec.), it is regarded as ‘the width of
pedestrian mode’. Then press the same button/button 4 to stop the gate, wait for some
seconds (1~ 44 sec.). Close the gate by pressing the same button/button 4. Press the
same button again to stop the gate or the gate will stop at its closed position automatically
if the limit switch is reached. After this setup is complete, return DIP-switch 1 to OFF
position immediately. Thus the
width of pedestrian mode
has been set.
If you open the gate with button 4, the gate will stop at the expected position that you have
set.
﹡
Set auto-close function of pedestrian mode: Please turn on the first and the second
DIP-switch (See Fig.9 terminal 18) to ON position. Press button 4 to open the gate (see
Verify open direction
section), wait some seconds (3~10 sec.). Then press the same
button/button 4 to stop the gate, wait some seconds according to your requirements (1~44
sec.), this period of time is regarded as ‘auto-close time of pedestrian mode’. Close the
gate by pressing the same button/button 4. Press the same button again to stop the gate or
the gate will stop at its closed position automatically if the limit switch is reached. After this
setup is complete, return DIP-switch 1 to OFF position immediately. Thus the
auto-close
function of pedestrian mode
has been set.
Note: the new width of pedestrian mode has been re-programmed in the device and
replaced the original width you have set in
Set width of pedestrian mode
section.
If you open the gate with button 4, the gate will stop at the new expected position that you
have set, after some seconds as what you have set, the gate will close automatically.