host will broadcast the previous configuration information, if you need to modify it, directly enter the new IP and press # to
save;
The IP address of center 1, format: 34+02+021052118056# (IP address of the computer or cloud server where the software
is installed)
Gateway, format: 34+05+192168001001# (fill in according to the network gateway address)
Subnet mask, format: 34+06+255255255000# (fill in according to the network information address)
Source UDP port 1, format: 35+01+20001# (the port through which the host sends data)
Destination UDP port 1, format: 35+04+03005# (software or server's data receiving port)
Center 1 heartbeat detection report time, format: 37+01+0030#
"*" key to exit programming
3. The user telephone alarm notice
1.Set alarm telephone number
Enter the password (default is 123456) +# to enter the programming;
Set the user's alarm telephone number, format: 18+N (that is telephone number 01-08) + telephone number (up to 16 digits) +#;
Note when setting the number: In case of transferring the group internal line to an external line during use, you should add the
outgoing office plus * (pause) + telephone # before entering the telephone number;
*#, exit programming;
2. Clear the phone number
Enter the password (default is 123456) +# to enter the programming;
Enter 18+N(01-08)+# to clear the phone number;
* Key to exit programming;
For example: the group outgoing number is 0, and the dialing user receives the alarm number 1. The programming is as follows:
Enter the password (default is 123456) +# to enter programming; 18+01+0+*+user #
Note: The "*" sign means to wait for 1 second, each additional "*" means that the waiting time increases by one second, press the
"#" key to end and save.
3. Hang up the phone
The panel alarms. After dialing the user's phone, the panel has the following three ways to hang up after the user answers:
1) The user hangs up after answering the phone for more than 12 seconds, and will not continue to dial the user's phone;
2) When the user answers the call for less than 12s and hangs up, it will continue to dial the user's phone, and the number of
dialing times will be the set number of dialing;
3) When the panel is disarmed, the user's phone will not continue to be dialed;
4. activate the SMS arm and disarm reminder function
Set the SMS number 1 to report the attributes in the instruction 31 programming item, and when the attribute 2 (zone alarm +
arming and disarming sending SMS) function is enabled, the panel will send this information to the corresponding mobile phone
whenever the panel performs arming, alarming and disarming actions. The content displayed by the mobile phone SMS message
is as follows: Arming information: XX arming; Disarming information: XX disarming; Alarm information: XX zone alarm.
Attachment: If you only need to send an alarm message to the first mobile phone number after the alarm is activated, the arm and
disarm and other information do not send SMS, you must set the following, 31+01+1, so that the panel will only send the zone
alarm to the first mobile phone number.
5. LoRa expansion modul
LoRa frequency 433MHZ;
Communication distance in open areas is 2 kilometers;
Maximum access to 40 zones;
Two-way reliable communication, equipment undervoltage/wireless strength monitoring;