AL-238
PPROGRAMMING GUIDE
12
1.10.Keypad lock and unlock
If keypad locked function is turned on, keypad disarming operates 3 times error password, and enters locked status. Only beep
when you press any key. The keypad will unlock automatically after15 minutes or cut off the control panel and restart.
1.11.Recovery keypad programming password is123456
<1>. Disconnect the keypad power.
<2>. Plug-in the keypad J1jumper.
<3>. Turn on the keypad power.
<4>. Plug-out the keypad J1jumper.
1.12.Modify keypad address
(1). Press and hold the [bypass] key on the keypad for more than 3 seconds; enter the keypad programming password: 6 digits,
the factory default password is 123456
(2). Press and hold the [*] key for 3 seconds. The programming light is always on to show that you have entered the programming
mode;
(3). Enter function code 0100 (function code is 4 digits);
(4). Enter a 2-digit keypad address such as 01 (keypad address is from 0 to 7, a total of 8 keypad addresses). If input correct, the
panel will make a long beep; if input wrong, it will issue a "di di di" 3 Sound error prompt, the keypad will automatically exit the
programming mode when the input is wrong, you must press the above operation again to enter the programming and enter the
correct programming value to succeed;
(5). During or after programming, just press and hold the "*" key for 3 seconds to exit the programming mode;
1.13.Recover the panel master password
Power off the panel, short-circuit the jumper J11 on the main board of the panel, and then power on the master password to
restore the default value; after the power off to reset the jumper J11 ;
1.14.Panel restore factory settings
Power off the panel, short-circuit the jumper J11 of the panel motherboard, and then power on, enter the password (123456) +#,
enter the programming, and then enter 44+02+1# to initialize immediately, and the panel will restore the factory settings and
restore after power off to reset jumper J11 ;
2.System programming instruction
Enter programming——input format: master password (6 digits) + # (factory default master password: 123456)
Note: Note: enter programming successfully, buzzer sounds a long beep, programming LED turns on voice broadcasts “enter
programming” which means the control panel is in state of programming.
Exit programming——Input format: under programming press “*”directly to exit programming.
Note: when exiting programming state, buzzer sounds a long beep, programming LED
turns off, or stop operating keypad in 30 seconds
,
control panel will exits automatically, buzzer does not sound
,
programming
LED turns off
3. Control panel programming list and each item default value
Attachment 1
Control panel query list:
Function
menu
Main
code
Sub-
code
Factory value/
programming
digits
Function
instruction
Allowed programming function
code range and operation