AL-238
PPROGRAMMING GUIDE
17
11+01+9+#, and it will prompt "Operation
successful";
Time
settings
12
01
010
(
3 digits
)
System alarm
time
Input Format
:
12+01+XXX+#
XXX means alarm time is 000-999s
,
default factory
value is 010s
02
010
(
3 digits
)
Keypad arming
delay
Input Format
:
12+02+XXX+#
XXX means keypad arming time is 000-
999s
,
default
factory value is 010s.
03
030
(
3 digits
)
Zone 1 enters
alarm delay
Input Format
:
12+03+XXX+#
XXX means zones 1 entry delay time is
000-999s
,
default factory value is 030s
…
…
…
…
42
030
(
3 digits
)
Zone 40 enters
alarm delay
Input Format
:
12+42+XXX+#
XXX means zones 40 entry delay time is
000-999s
,
default factory value is 030s.
43
000
(
3 digits
)
Power-on time
restricts alarm
Input Format
:
12+43+XXX+#
XXX means that the system power-on
time restricts
alarm time is
000-999 s , default factory value 000s
;
44
000
(
3 digits
)
Siren prompt
after arming
is completed
Input Format
:
12+44+XXX+#
XXX means time of siren alarm after arm
completed
is 000-999s
,
default factory value
is000s.
Arm
quickly/
Force
arming/
system low
voltage/
Reminder of
delay
Zones/
keypad
locked/
AC test/
battery test
13
01
1
(
1 digit
)
Quick arming
operation allows
Input Format
:
12+01+X+#
X indicates
:
0 means forbid, while 1
means allow.
Default factory value is 1.
Function description: If the function is
turned on, long press the arm button for
3 seconds to start arming;After this
function is turned on, you do not need to
enter a password to arm , but you must
enter the password to disarm , if the
function is turned off, you need to enter
the password to arm or disarm;
02
1
(
1 digit
)
Force arming
turn on/off
Input Format
:
12+02+X+#
X indicates
:
0 means forbid, while 1
means allow.
Default factory value is 1.
Function instruction
:
The
function is turned on
,
the fault zone
can be armed directly. If the function is
off,
it is not allowed to arm in faulty zone.
03
0
(
1 digit
)
System
undervoltage
buzzer prompt
Input Format
:
12+03+X+#
X indicates
:
0 means forbid, 1 means
allow.
Default factory value is 0.