PLASMA CUTTER
22
1300 777 137
AUS
AFTER SALES SUPPORT
PLASMA 35 60485 04/2018
Arc stops while cutting
• Cutting speed too slow
• Lack of air flow while
cutting
• Worn torch consumables
• Duty cycle of the plasma
cutter exceeded.
• Increase speed until problem
solved.
• You may need a larger air
compressor which can
maintain the required
pressure and air flow.
• Inspect and repair or replace
worn parts.
• Allow the unit to cool for 15
minutes before resuming.
Insufficient penetration
• Cutting speed too fast
• Torch tilted too much
• Metal too thick
• Worn torch consumables
• Slow cutting speed
• Adjust tilt.
• Several passes may be
necessary
• Inspect and repair or replace
worn parts
Consumables wear
quickly
• Exceeding unit's capability
• Improperly assembled
torch
• Inadequate air supply,
pressure too low.
• Not recommended to
continue cutting.
Note the operator may still
wish to continue the cut but it
will cost them in consumable
items.
• Check the torch and
consumables.
• You may need a larger air
compressor which can
maintain the required
pressure and air flow.
TROUBLESHOOTING