PLASMA CUTTER
13
1300 777 137
AUS
AFTER SALES SUPPORT
PLASMA 35 60485 04/2018
will activate and cut off the welding current. If the
overload cut out protector activates leave the plasma
cutter for at least 15 minutes to cool down before
further use.
6. THE RATING PLATE
The rating plate is fitted to the plasma cutter and displays the following symbols
and information.
Single phase,
frequency conversion,
D.C. output.
AS60974-1 Applicable
standard.
Plasma Cutting.
X
Duty cycle.
Case protection
rating.
I
2
Output current.
Mains supply single
phase A.C.
U
2
Output voltage.
U
0
No Load output
voltage.
I
1max
Maximum input
current.
U
1
Rated input voltage.
I
1eff
Rated input
current.
13.5A/85.4V - 35A/94V Rated output voltage and current range.
IP21S
RATING PLATE