Command Bytes:
<d>RJ
Parameters:
<d>
is either
C
followed by a channel number in ASCII,
P
followed by a channel
pair number in ASCII, or
G
followed by a channel group number in ASCII
Comments:
Channel numbers range from 1 through 16, Channel Pairs from 1 through 8, and
Channel Groups from 1 through 13. Use “*” for All Channels.
Message Response:
R
Examples:
Stop Channel Pair 2.
P2RJ
Stop Channel Group 1.
G1RJ