![Alcohol Countermeasure Systems Alcolock LR Installation And Service Manual Download Page 20](http://html.mh-extra.com/html/alcohol-countermeasure-systems/alcolock-lr/alcolock-lr_installation-and-service-manual_2892541020.webp)
ALCOLOCK LR
15
4. Mount the female connector of the OBD-II cable
assembly in place of the connector detached in step two.
5. Locate the white, 5-pin connector from the ECU cable
and place the black heat shrink (79-000262) over it. Do
not seal heat shrink until instructed.
6. Connect the 5-pin white connector from the ECU cable
to the 5-pin port of the OBD-II cable assembly (on the
electrical box).
7. Use supplied tie wraps to neatly incorporate the OBD-
II cable assembly with the vehicle wire loom. Keep
cabling away from vehicle components that move, or that
become excessively hot.
15.0 ATTACHING THE HS AND ECU
Before attaching the HS and the ECU, the ECU must be mounted and all ECU
wires must be connected.
ATTENTION! Do not solder or apply heat shrinks or tamper-proof labels until all wires
have been attached and post-installation testing has been performed.
1. Connect the ECU cable (13-001102) to the ECU main
input. The cable clicks into place and the ECU beeps.
2. Connect the non-coiled end of the HS cable (13-001100)
to the ECU HDMI port.
ATTENTION! Do not install the HS enclosure until instructed.