October 2006
Booting OmniSwitch 6800 Series Switches
19
Booting a Standalone Switch
The OmniSwitch 6800 Series switch does not use an on/off
switch. The power cord is the switch’s only connect/discon-
nect device. The power connector socket is located on the
switch’s rear panel. For more information, refer to
“OmniSwitch 6800 Series Rear Panel” on page 59
.
To boot the switch, plug the power cord (provided) into the
power connector socket at the switch’s rear panel. Next, plug
the power cord into an easily-accessible power source, such as
a grounded AC outlet or an Uninterruptible Power Supply
(UPS).
The switch immediately begins the boot process. Allow a few
moments for the switch to boot completely, then verify the
status of all LEDs on the switch’s front panel. A successful
boot for a standalone switch displays the following LED
states:
If any of the LED state differs from the states shown in the
table above, refer to
page 58
for more information. Contact
Alcatel Customer Support if the unexpected LED state
persists.
Booting OmniSwitch 6800 Series Switches
LED States for a Standalone Switch
OK
Solid green
PRI
Solid green
PWR
Solid green
BPS
Solid amber if no operational backup
power supply (BPS) is attached; solid
green if an operational BPS is
attached. See
page 58
for more infor-
mation.
FAN
Solid green
TMP
Solid green
XFP1
Off
XFP2
Off
Slot Indicator
1–8 (non-blinking), depending on the
slot number value in the
boot.slot.cfg
file. See the
OmniSwitch 6800 Series
Hardware Users Guide
for detailed
information. The default value is 1.
LED States for a Standalone Switch