ED
03
8DG 15436 BAAA
108/140
4.38.
Housekeeping and Remote Alarms Connections
(Refer to Figure 82. on page 108)
These connections are directly made on the connector C2 mounted on the “Control and General I/F unit
(CONGI)”. inserted into slot 10 and 12.
•
Wire-connect alarms onto SUB.D 15 P male connector (1AB 003110022)
•
Close the connector into the relevant SUB.D 15 Shell connector (1AB 006030063)
The SUB.D 15 P connector and shell are inside the “S9 Installation Kit” (3AL78913AA).
CONGI
1
8
9
15
PIN
FUNCTION
CABLE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
GND
(*) NURG:Not urgent alarm
(*) URG :Urgent alarm
TOR:OR battery
TAND:AND batteries
INT:Internal alarm
HK-OUT1:Output parellel contact 1
HK-OUT2:Output parallel contact 2
T*GND_IN_RA
HK-IN6:Input parallel contact 6
HK-IN5:Input parallel contact 5
HK-IN4:Input parallel contact 4
HK-IN3:Input parallel contact 3
HK-IN2:Input parallel contact 2
HK-IN1:Input parallel contact 1
SLOT 10, 12
Housekeeping and remote alarm
2
1
8
9
15
Pair 4
Pair 3
Pair 5
Pair 6
Pair 8
Pair 7
Pair 1
Pair 2
Pair 8
8 pairs shielded
Wire-Wrap cable
SUB.D 15 P male connector
1AB 003110022
white
blue
white
white
white
white
orange
brown
green
grey
red
red
red
blue
orange
green
Connection side wiew
IF INSERTED IN SLOT 10
FUNCTION
IF INSERTED IN SLOT 12
GND
LOSQ2
TANC: loss of 3.3 V on one CONGI
TORC: loss of 3.3 V on both CONGI
IND: indeterminate alarm (not used)
TUP: microprocessor fault
HK-OUT3:Output parellel contact 3
HK-OUT4:Output parellel contact 4
HK-IN12:Input parallel contact 12
HK-IN11:Input parallel contact 11
HK-IN10:Input parallel contact 10
HK-IN9:Input parallel contact 9
HK-IN8:Input parallel contact 8
HK-IN7:Input parallel contact 7
C2
C2
N.B.: This figure can change
if a different cable is used .
T*GND_IN_RA
Figure 82. Housekeeping and Remote Alarm connections
See
Annex B
on page
138
Summary of Contents for 1660SM
Page 2: ...8DG 15436 BAAA Ed 03 2 140...
Page 12: ...ED 03 8DG 15436 BAAA 12 140 This page is intentionally blank...
Page 22: ...ED 03 8DG 15436 BAAA 22 140 Figure 5 Use of the extraction tools...
Page 30: ...ED 03 8DG 15436 BAAA 30 140 Figure 13 19 fan shelf...
Page 58: ...ED 03 8DG 15436 BAAA 58 140 Figure 30 Cable assembly for STM 1 Electrical module ICMI...
Page 120: ...ED 03 8DG 15436 BAAA 120 140 This page is intentionally blank...
Page 126: ...ED 03 8DG 15436 BAAA 126 140 This page is intentionally blank...
Page 130: ...ED 03 8DG 15436 BAAA 130 140 This page is intentionally blank...